Type | NB48-10KDZ | NB96-10KDZ | NB120-10KDZ | NB240-10KDZ | |
DC input | Input rated voltage | 48 VDC | 96 VDC | 120 VDC | 240 VDC |
Input rated current | 231 A | 116 A | 93 A | 46 A | |
Input DC voltage range | 40-62 VDC | 80-124 VDC | 100-155 VDC | 200-310 VDC | |
AC input | Allow input voltage range | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% VAC | |||
Input rated current | 91A / 104A / 45.5 A / 42A | ||||
Bypass transfer time | ≤40 ms(Can be customized ≤4ms version) | ||||
AC output | Output rated power | 10KW | |||
Output rated voltage and frequency | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | ||||
Output rated current | 91A / 104A / 45.5 A /42A | ||||
Output voltage accuracy | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 1% | ||||
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||||
Waveform distortion (THD). | ≤3% (Linear load) | ||||
Dynamic response time (Load 0←→100%) |
2ms | ||||
Power factor (PF) | 1 | ||||
Overload capacity | 120%,5 minutes;200%,3 seconds | ||||
Crest factor (CF) | 3:1 | ||||
Inverter efficiency | 94% | ||||
Working Environment | Dielectric strength | 1500VAC,1minute | |||
Noise (1m) | ≤50dB | ||||
Ambient temperature | -20ºC~+60ºC | ||||
Humidity | 0~90%, No condensation | ||||
Altitude | <6000m Higher than 2000m rated power should be reduced | ||||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||||
Equipped with isolated transformer | Yes | ||||
Pure Sine Wave | Yes | ||||
AC Charger | Available, optional | ||||
Solar Battery Charger | Available, optional | ||||
Dry Contact | Available. optional | ||||
Size | 550*480*1200mm | ||||
Weight | 130kg |
Type | NB48-15KDZ | NB96-15KDZ | NB120-15KDZ | NB240-15KDZ | |
DC input | Input rated voltage | 48 VDC | 96 VDC | 120 VDC | 240 VDC |
Input rated current | 347 A | 174 A | 139 A | 69 A | |
Input DC voltage range | 40-62 VDC | 80-124 VDC | 100-155 VDC | 200-310 VDC | |
AC input (AC Bypass) |
Allow input voltage range | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% VAC | |||
Input rated current | 136A / 125A / 68A / 62.5A | ||||
Bypass transfer time | ≤100 ms(Can be customized ≤4ms version) | ||||
AC output | Output rated power | 15KW | |||
Output rated voltage and frequency | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | ||||
Output rated current | 136A / 125A / 68A / 62.5A | ||||
Output voltage accuracy | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 1% | ||||
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||||
Waveform distortion (THD). | ≤3% (Linear load) | ||||
Dynamic response time (Load 0←→100%) |
2ms | ||||
Power factor (PF) | 1 | ||||
Overload capacity | 120%,5 minutes;200%,3 seconds | ||||
Crest factor (CF) | 3:1 | ||||
Inverter efficiency | 94% | ||||
Working Environment | Dielectric strength | 1500VAC,1 minute | |||
Noise (1m) | ≤50dB | ||||
Ambient temperature | -20ºC~+60ºC | ||||
Humidity | 0~90%, No condensation | ||||
Altitude | <6000m (Higher than 2000m rated power should be reduced) |
||||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||||
Equipped with isolated transformer | Yes | ||||
Pure Sine Wave | Yes | ||||
AC Charger | Available, optional | ||||
Solar Battery Charger | Available, optional | ||||
Dry Contact | Available. optional | ||||
Size | 550*480*1200mm | ||||
Weight | 200kg |
Type | NB48-20KDZ | NB96-20KDZ | NB120-20KDZ | NB240-20KDZ | |
DC input | Input rated voltage | 48 VDC | 96 VDC | 120 VDC | 240 VDC |
Input rated current | 463 A | 231 A | 185 A | 93 A | |
Input DC voltage range | 40-62 VDC | 80-124 VDC | 100-155 VDC | 200-310 VDC | |
AC input (AC Bypass) |
Allow input voltage range | 110 VAC /120 VAC /220 VAC /240 VAC ± 15% VAC | |||
Input rated current | 182A / 167A / 91 A / 83A | ||||
Bypass transfer time | ≤100 ms(Can be customized ≤4ms version) | ||||
AC output | Output rated power | 20KW | |||
Output rated voltage and frequency | 110 VAC / 120 VAC / 220 VAC / 240 VAC ,50Hz / 60Hz | ||||
Output rated current | 182A / 167A / 91 A / 83A | ||||
Output voltage accuracy | 110 VAC / 120 VAC / 220 VAC / 240 VAC±1% | ||||
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||||
Waveform distortion (THD). | ≤3% (Linear load) | ||||
Dynamic response time (Load 0←→100%) |
2ms | ||||
Power factor (PF) | 1 | ||||
Overload capacity | 120%,5 minutes;200%,3 seconds | ||||
Crest factor (CF) | 3:1 | ||||
Inverter efficiency | 90% | ||||
Working Environment | Dielectric strength | 1500VAC,1minute | |||
Noise (1m) | ≤50dB | ||||
Ambient temperature | -20ºC~+60ºC | ||||
Humidity | 0~90%, No condensation | ||||
Altitude | <6000m Higher than 2000m rated power should be reduced | ||||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||||
Equipped with isolated transformer | Yes | ||||
Pure Sine Wave | Yes | ||||
AC Charger | Available, optional | ||||
Solar Battery Charger | Available, optional | ||||
Dry Contact | Available. optional | ||||
Size | 610*950*1300mm | ||||
Weight | 210kg |
30KW off grid single phase inverter technical parameters
Type | NB120-30KDZ | NB240-30KDZ | NB380-30KDZ | |
DC input | Input rated voltage | 120 VDC | 240 VDC | 380 VDC |
Input rated current | 278 A | 139 A | 88 A | |
Input DC voltage range | 100-155 VDC | 200-310 VDC | 320-496VDC | |
AC input (AC Bypass) |
Allow input voltage range | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% VAC | ||
Input rated current | 272A / 250A / 136 A /125A | |||
Bypass transfer time | ≤100 ms(Can be customized ≤4ms version) | |||
AC output | Output rated power | 30KW | ||
Output rated voltage and frequency | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | |||
Output rated current | 272A / 250A / 136 A /125A | |||
Output voltage accuracy | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 1% | |||
Output frequency accuracy | 50Hz / 60Hz ±0.05% | |||
Waveform distortion (THD). | ≤3% (Linear load) | |||
Dynamic response time (Load 0←→100%) |
2ms | |||
Power factor (PF) | 1 | |||
Overload capacity | 120%,5 minutes;200%,3 seconds | |||
Crest factor (CF) | 3:1 | |||
Inverter efficiency | 94% | |||
Working Environment | Dielectric strength | 1500VAC,1minute | ||
Noise (1m) | ≤50dB | |||
Ambient temperature | -20ºC~+60ºC | |||
Humidity | 0~90%, No condensation | |||
Altitude | <6000m Higher than 2000m rated power should be reduced | |||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |||
Equipped with isolated transformer | Yes | |||
Pure Sine Wave | Yes | |||
AC Charger | Available, optional | |||
Solar Battery Charger | Available, optional | |||
Dry Contact | Available. Optional | |||
Size(mm) | 800*600*2260mm | |||
Weight(kg) | 360kg |