Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 14914/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Type | NB380-200KSZ | NB480-200KSZ | |
DC input | Input rated voltage | 380 VDC | 480 VDC |
Input rated current | 585 A | 463 A | |
Input DC voltage range | 320-496 VDC | 400-620 VDC | |
AC input (AC Bypass) |
Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
Input rated current | 550A / 300A / 290A | ||
Bypass transfer time | ≤100ms(Can be customized ≤4ms version) | ||
AC output | Output rated power | 200KW | |
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC ,50Hz / 60Hz | ||
Output rated current | 550A / 300A / 290A | ||
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | ||
Output frequency accuracy | 50Hz / 60Hz ±0.05% | ||
Waveform distortion (THD). | ≤3% (Linear load) | ||
Dynamic response time (Load 0←→100%) |
2ms | ||
Power factor (PF) | 1 | ||
Overload capacity | 120%,5 minutes;200%,3 seconds | ||
Crest factor (CF) | 3:1 | ||
Inverter efficiency | 94% | ||
Working Environment | Dielectric strength | 1500VAC,1minute | |
Noise (1m) | ≤50dB | ||
Ambient temperature | -20ºC~+60ºC | ||
Humidity | 0~90%, No condensation | ||
Altitude | <6000m Higher than 2000m rated power should be reduced | ||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
Pure Sine Wave | Yes | ||
Equipped with copper transformer | Yes | ||
Communication mode | RS485,Wifi,GPRS,Ethernet (Modbus RTU protocol) | ||
AC Charger | Optional | ||
Solar Charger | Optional | ||
Generator port | Optional | ||
Size(mm) | 1600*1000*2000mm | ||
Weight(kg) | 1400kg |
Type | NB384-300KSZ | NB480-300KSZ | |
DC input | Input rated voltage | 384 VDC | 480 VDC |
Input rated current | 860 A | 690 A | |
Input DC voltage range | 320-500 VDC | 400-620 VDC | |
AC input (AC Bypass) |
Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
Input rated current | 830A / 450A / 430A | ||
Bypass transfer time | ≤100ms (Can be customized ≤ 4ms version) | ||
AC output | Output rated power | 300KW | |
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC ,50Hz / 60Hz | ||
Output rated current | 830A / 450A / 430A | ||
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | ||
Output frequency accuracy | 50Hz / 60Hz ±0.05% | ||
Waveform distortion (THD). | ≤3% (Linear load) | ||
Dynamic response time (Load 0←→100%) |
2ms | ||
Power factor (PF) | 1 | ||
Overload capacity | 120%,5 minutes;200%,3 seconds | ||
Crest factor (CF) | 3:1 | ||
Inverter efficiency | 96% | ||
Working Environment | Dielectric strength | 1500VAC,1minute | |
Noise (1m) | ≤50dB | ||
Ambient temperature | -20ºC~+60ºC | ||
Humidity | 0~90%, No condensation | ||
Altitude | <6000m Higher than 2000m rated power should be reduced | ||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
Pure Sine Wave | Yes | ||
Equipped with copper transformer | Yes | ||
Communication mode | RS485,Wifi,GPRS,Ethernet (Modbus RTU protocol) | ||
AC Charger | Optional | ||
Solar Charger | Optional | ||
Generator port | Optional | ||
Product Size | 1910*1160*1880mm | ||
Product Weight | 1500kg |
Type | NB480-400KSZ | |
DC input | Input rated voltage | 480 VDC |
Input rated current | 926 A | |
Input DC voltage range | 400-620 VDC | |
AC input (AC Bypass) |
Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC |
Input rated current | 1024A / 608A / 580A | |
Bypass transfer time | ≤100ms(Can be customized ≤4ms version) | |
AC output | Output rated power | 400KW |
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC ,50Hz / 60Hz | |
Output rated current | 1024A / 608A / 580A | |
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | |
Output frequency accuracy | 50Hz / 60Hz ±0.05% | |
Waveform distortion (THD). | ≤3% (Linear load) | |
Dynamic response time (Load 0←→100%) |
2ms | |
Power factor (PF) | 1 | |
Overload capacity | 120%,5 minutes;200%,3 seconds | |
Crest factor (CF) | 3:1 | |
Inverter efficiency | 96% | |
Working Environment | Dielectric strength | 1500VAC,1minute |
Noise (1m) | ≤50dB | |
Ambient temperature | -20ºC~+60ºC | |
Humidity | 0~90%, No condensation | |
Altitude | <6000m Higher than 2000m rated power should be reduced | |
Equipped with copper transformer | Yes | |
Pure Sine Wave | Yes | |
Communication mode | RS485,Wifi,GPRS,Ethernet (Modbus RTU protocol) | |
AC Charger | Optional | |
Solar Charger | Optional | |
Generator port | Optional | |
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |
Product Size | 1910*1160*1880mm | |
Product Weight | 1500-1800kg |