Customization: | Available |
---|---|
Nature of Source Flow: | Passive inverter |
Certification: | ISO9001, CE |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Energy flows bi-directionally, i.e. it can discharge from the battery side to the DC grid or charge from the DC grid side to the battery;
Fully automatic protection functions for overheating, overload, short circuit, overcurrent, etc;
Selection of original imported power devices;
Fully digital circuit design;
All the chips are industrial grade and can operate normally in cold, high temperature and humid environment;
The main circuit adopts DSP chip produced by TI of America, Infineon IGBT module and Infineon movement for driving and protection, which is safe and reliable;
The output is automatically synchronized with the grid, the current harmonic content is low, and there is no pollution and impact on the grid;
Closed loop control of grid connected current, controllable and adjustable;
Wide input voltage range, suitable for different occasions;
The system has all-round power protection scheme and perfect self-test and protection function. In case of system failure, it will stop working;
The circuit structure is compact and the maximum efficiency ≥ 96%;
Protection level can be customized according to the user's needs;
Provide Ethernet interface, standard Modbus TCP communication protocol.
Rated power |
250KW |
LV rated current |
358A MAX:716A |
LV voltage range |
600-700Vdc |
Ripples coefficient |
HV side < 1% F.S. LV side < 2% F.S. |
Control accuracy |
< 1%(Remote and local control, @ full load) |
Max. efficiency |
96% @ full load |
Switching frequency on IGBTs |
6kHz |
HV Voltage range |
900-1314Vdc |
Dynamic response time |
<2ms |
Protection function |
Reverse polarity, overheating, overload, overvoltage, overcurrent, undervoltage, etc |
Display |
Touch screen |
Time propagation |
200ms |
Communication interface and protocol |
Modbus_ TCP, RJ45 Modbus_ RTU, RS485 |
RS485 interface number |
one |
Working temperature |
-10ºC to +50ºC |
Relative humidity |
0~95%,No condensation |
Altitude |
≤2000m(More than 2000 meters need to be reduced) |
Cooling mode |
Air cooling |
Noise |
≤65dB |
Emergency stop switch |
yes |
Level of protection |
IP55 |
System electrical input |
AC230V 50/60Hz 1000W |
Rated power | 500KW |
LV rated current | 667A MAX:734A |
LV voltage range | 680-790Vdc |
Ripples coefficient | HV side < 1% F.S. |
LV side < 2% F.S. | |
Control accuracy | < 1%(Remote and local control, @ full load) |
Max. efficiency | 98% @ full load |
Switching frequency on IGBTs | 6kHz |
HV Voltage range | 900-1314Vdc |
Dynamic response time | <2ms |
Protection function | Reverse polarity, overheating, overload, overvoltage, overcurrent, undervoltage, etc |
Display | Touch screen |
Time propagation | 200ms |
Communication interface and protocol | Modbus_ TCP, RJ45 Modbus_ RTU, RS485 |
RS485 interface number | one |
Working temperature | -10ºC to +50ºC |
Relative humidity | 0~95%,No condensation |
Altitude | ≤2000m(More than 2000 meters need to be reduced) |
Cooling mode | Air cooling |
Noise | ≤65dB |
Emergency stop switch | yes |
Level of protection | IP55 |
System electrical input | AC220V 1000W |