• 600kw 800kw 1000kw Alternator Genrator Eco-Friendly Generator for Water Hydro Generator with Inverter
  • 600kw 800kw 1000kw Alternator Genrator Eco-Friendly Generator for Water Hydro Generator with Inverter
  • 600kw 800kw 1000kw Alternator Genrator Eco-Friendly Generator for Water Hydro Generator with Inverter
  • 600kw 800kw 1000kw Alternator Genrator Eco-Friendly Generator for Water Hydro Generator with Inverter
  • 600kw 800kw 1000kw Alternator Genrator Eco-Friendly Generator for Water Hydro Generator with Inverter
  • 600kw 800kw 1000kw Alternator Genrator Eco-Friendly Generator for Water Hydro Generator with Inverter

600kw 800kw 1000kw Alternator Genrator Eco-Friendly Generator for Water Hydro Generator with Inverter

Output Type: AC Three Phase
Cooling
Method:
Wind Cooling
Installation
Method:
Fixed
Generator
Type:
Hydro Generator
Transport Package: Wooden Case
Specification: 7000KG
Samples:
US$ 13500/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Our Advantages
  • More products
  • Company Profile
Overview

Basic Info.

Model NO.
PMG-800KW
Trademark
Deming
Origin
China Jinan
HS Code
85016300
Production Capacity
50000/Year

Product Description

Product Description

400KW 1800RPM  PMG Hydraulic permanent magnet generatorCharacteristics
600kw 800kw 1000kw Alternator Genrator Eco-Friendly Generator for Water Hydro Generator with Inverter

1. Optimum aerodynamic shape design: high efficiency, low noise.

2. Centrifugal pitch controlled mechanism: 3m/s low wind speed startup; 3-12m/s wind speed, following wind rotor rotate speed to adjust blade angle at optimum TSR, run in high efficiency; over rated wind speed, wind rotor never goes to over speed and has stable control; 3-35m/s wind speed, wind turbine can run smoothly.

3. Direct drive permanent magnet generator, low startup resistance moment, constant running ability of over loading 1.5 times, maintenance free for more than 30000 hour. 

4. Safety control: has aerodynamic brake, electric magnet brake, mechanical brake and manual stop mechanism.

5. Sealed slip ring, no cable twist;

6. Streamline design. 

7. Long acting anticorrosive treats, no corrosion in 15years.  
 

Detailed Photos

600kw 800kw 1000kw Alternator Genrator Eco-Friendly Generator for Water Hydro Generator with Inverter

600kw 800kw 1000kw Alternator Genrator Eco-Friendly Generator for Water Hydro Generator with Inverter600kw 800kw 1000kw Alternator Genrator Eco-Friendly Generator for Water Hydro Generator with Inverter600kw 800kw 1000kw Alternator Genrator Eco-Friendly Generator for Water Hydro Generator with Inverter

Product Parameters

600kw 800kw 1000kw Alternator Genrator Eco-Friendly Generator for Water Hydro Generator with Inverter600kw 800kw 1000kw Alternator Genrator Eco-Friendly Generator for Water Hydro Generator with Inverter

600kw 800kw 1000kw Alternator Genrator Eco-Friendly Generator for Water Hydro Generator with Inverter

On grid wind turbine controller WGMC50K380 WGMC100K380 WGMC200K380
Wind turbine input
Power 50KW 100KW 200KW
Max. Control power / current 100KW/200A 200KW/400A 400KW/800A
Rated voltage of wind turbine (AC) 380V/400V 380V/400V 380V/400V
Input voltage range AC 0-600V 0-600V 0-600V
DC 0-900V 0-900V 0-900V
Braking voltage (DC) Default 550V±1% 550V±1% 550V±1%
Set range 530-560V 530-560V 530-560V
Braking current (DC) Default 150A 300A 600A
Set range 0-150A 0-300A 0-600A
Braking time Default 10-20 min
Set range 0-5000 min
* Generator overspeed control Default >300 rpm/min
Set range 0-1000 rpm/min
* Over wind speed control Default 14 m/s
Set range 0-45 m/s
Manual control Manual brake , *remote control brake (with communication function)
Automatic control function Dump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake,
* electromagnetic brake
DC output parameters
Output voltage range (DC) 0-550V 0-550V 0-550V
Constant voltage (DC) Default 520V±1% 520V±1% 520V±1%
Set range 510-540V 510-540V 510-540V
Constant current (DC) Default 120A 240A 480A
Set range 0-120A 0-240A 0-480A
On grid wind turbine inverter DMWG50K DMWG100K DMWG200K
Rated output power (AC) 50KW 100KW 200KW
Max. Output power (AC) 55KW 110KW 220KW
Input voltage rang (DC) 0-800V 0-800V 0-800V
MPPT Voltage range (DC)(DC) 150V-700V 150V-700V 150V-700V
Max. Input current (DC) 114.6A 229A 458.3A
Rated current 104A 208A 416.7A
THD Current harmonic <3%(at rated power)
Power factor >0.99
Max. efficiency 96%
Allowable grid voltage range (AC) 220V/380V/440V/480V (Three-phase)±20%
Allowable grid frequency range 50Hz/60Hz±10%
Automatic operation conditions DC input and power grid meet the requirements, and the inverter operates automatically
Restart time after power failure 2min(Adjustable)
General parameters
Function Rectification, DC output, output voltage control, output current control, Dump load control, control parameter setting, wind turbine curve setting
Automatic protection Control part: Over voltage protection, over current protection, reverse connection protection, lightning arrester
Inverter part: Polarity reverse connection protection, short circuit protection, island effect protection, LVRT,overheat protection, overload protection, ground fault protection, etc
Display Touch screen, LCD
Monitoring content Wind turbine voltage, current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speed
Protection level IP20(Indoor)IP65 (Outdoors)
Telematics RS485/USB/GPRS/WIFI/Ethernet (optional)
Environment Operating amb. Temp. & Hum  -30-60°C,<90% no condensation
Noise (1m) <40dB
Refrigeration mode Forced air cooling
 
Controller size / weight 500*500*900mm   56kg 600*500*1200mm    107kg 950*550*1700mm    150kg
Dump load size / weight 920*770*380mm   80kg 920*770*380mm*2   150kg   923*739*510mm*4   280kg
Inverter size / weight 750*600*1320mm  340kg 1460*860*1820mm   1.4t 1460*860*1820mm   1.6t
               
 
On grid wind turbine controller WGMC10K380 WGMC20K380 WGMC30K380
Wind turbine input
Power 10KW 20KW 30KW
Max. Control power / current 20KW/40A 40KW/80A 60KW/120A
Rated voltage of wind turbine (AC) 380V/400V 380V/400V 380V/400V
Input voltage range AC 0-600V 0-600V 0-600V
DC 0-900V 0-900V 0-900V
Braking voltage (DC) Default 550V±1% 550V±1% 550V±1%
Set range 530-560V 530-560V 530-560V
Braking current (DC) Default 30A 60A 90A
Set range 0-30A 0-60A 0-90A
Braking time Default 10-20 min
Set range 0-5000 min
* Generator overspeed control Default >300 rpm/min
Set range 0-1000 rpm/min
* Over wind speed control Default 14 m/s
Set range 0-45 m/s
Manual control Manual brake, *remote control brake (with communication function)
Automatic control function Dump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake,
* electromagnetic brake
* PV. Input
Rated power (increased) 5KWp 5KWp 5KWp
Working voltage (DC) 550V / 660V 550V / 660V 550V / 660V
DC output parameters
Output voltage range (DC) 0-550V 0-550V 0-550V
Constant voltage (DC) Default 520V±1% 520V±1% 520V±1%
Set range 510-540V 510-540V 510-540V
Constant current (DC) Default 24A 48A 72A
Set range 0-24A 0-48A 0-72A
On grid wind turbine inverter DMWG10KTL DMWG20KTL DMWG30KTL
Rated output power (AC) 10KW 20KW 30KW
Max. Output power (AC) 11KW 22KW 33KW
Input voltage rang (DC) 0-800V 0-800V 0-800V
MPPT Voltage range (DC)(DC) 150V-700V 150V-700V 150V-700V
Max. Input current (DC) 2.4A 44.9A 67.3A
Rated current 20.4A 40.8A 61.2A
THD Current harmonic <3%(at rated power)
Power factor >0.99
Max. efficiency 98%
Allowable grid voltage range (AC) 220V/380V/440V/480V (Three-phase)±20%
Allowable grid frequency range 50Hz/60Hz±10%
Automatic operation conditions DC input and power grid meet the requirements, and the inverter operates automatically
Restart time after power failure 2min(Adjustable)
General parameters
Function Rectification, DC output, output voltage control, output current control, Dump load control, control parameter setting, wind turbine curve setting
Automatic protection Control part: Over voltage protection, over current protection, reverse connection protection, lightning arrester
Inverter part: Polarity reverse connection protection, short circuit protection, island effect protection, LVRT,overheat protection, overload protection, ground fault protection, etc
Display Touch screen, LCD
Monitoring content Wind turbine voltage, current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speed
Protection level IP20(Indoor)IP65 (Outdoors)
Telematics RS485/USB/GPRS/WIFI/Ethernet (optional)
Environment Operating amb. Temp. & Hum  -30-60°C,<90% no condensation
Noise (1m) <40dB
Refrigeration mode Forced air cooling
 
Controller size / weight 400*230*550mm   23kg 500*230*620mm    35kg 500*230*620mm    38kg
Dump load size / weight 690*450*530mm   36kg 980*880*540mm    70kg 980*880*540mm    70kg
Inverter size / weight 690*275*770mm   42kg 690*275*770mm    58kg 690*275*770mm    65kg
             

*Above parameter only for reference. Could be custom made to user specifications.
 
Certifications

600kw 800kw 1000kw Alternator Genrator Eco-Friendly Generator for Water Hydro Generator with Inverter

Our Advantages

600kw 800kw 1000kw Alternator Genrator Eco-Friendly Generator for Water Hydro Generator with Inverter

More products

600kw 800kw 1000kw Alternator Genrator Eco-Friendly Generator for Water Hydro Generator with Inverter

Company Profile

 


600kw 800kw 1000kw Alternator Genrator Eco-Friendly Generator for Water Hydro Generator with Inverter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
55
Year of Establishment
2004-03-22