Customization: | Available |
---|---|
Nature of Source Flow: | Passive inverter |
Output Power: | >1000W |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
For more information, please visit Jinan Deming Power Equipment Co., Ltd.
Experience the power of our advanced solar inverter technology with the Deming 50kw Solar Hybrid Inverter Split Phase. This reliable and efficient inverter is designed to provide renewable energy for off-grid wind turbine power systems. With its versatile split phase capabilities and pure sine wave output, it's the perfect solution for your off-grid power needs.
Experience the power of our advanced, reliable, and efficient 50kw solar hybrid inverter. With cutting-edge technology and versatile split phase capabilities, it's the perfect choice for your renewable energy needs.
Model | NB220-50KSZ | NB110-50KSZ | NB96-50KSZ | NB48-50KSZ |
Rated Capacity | Output two phase 50KW | |||
Circuit Mode | IGBT/PWM | |||
DC Input | ||||
Input Rated Current | DC220V | DC110V | DC96V | DC48V |
Input DC voltage Range | DC180-300V | DC80-145V | DC75V-135V | DCC40V-60V |
Input Rated Current | 227A | 454.5A | 520A | 1041A |
AC Output | ||||
Output Mode | Two phase three wires | |||
Output Wave | Pure Sine Wave | |||
Output Voltage | L1-N: 110Vac/120Vac, L2-N: 110Vac/120Vac, L1-L2: 220Vac/240Vac | |||
Output Voltage accuracy | ±1% | |||
Output frequency | 50Hz | |||
Output frequency accuracy | ±0.01% | |||
Rated capacity | 50KVA | |||
Output rated power | 50KW | |||
Output Rated ampere | 227A | |||
Maximum output over current | 250A | |||
Maximum nominal current of loads | 227A | |||
Power factor | 1 | |||
Overload capacity | 120% 109A ,3 minutes,150% 136.4A,10 seconds | |||
Dynamic voltage transient range | 2%(0~100% load change) | |||
VTHD(Distortion) | THD<3%( non-linear load) | |||
Display Mode | ||||
Display Window | High accuracy four-in-one LED display | |||
Four digit voltmeter | Accuracy 0.1V | |||
Four digit ampere meter | Accuracy 0.1A | |||
Four digit frequency meter | Accuracy 0.1Hz | |||
Four digit power/power factor meter | Accuracy 0.1W | |||
System | ||||
System efficiency | Normal mode: 94% | |||
insulation resistance | DC> 500V 20MΩ | |||
insulating strength | (Input and output to ground)1800Vdc, leakage current<3.5mA, No-arcing for 1 min |
|||
Protection Class | IP22 | |||
Wiring method | Input and output wiring terminals,line bank | |||
Thermal methods | Transformer forced fan cooling | |||
Working temperature | -10ºC~+50ºC | |||
Relative humidity | 0-90%(No condensation) | |||
Noise(dB) | <65dB | |||
Protection Function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |||
Equipped with AC Bypass | Yes | |||