Power Frequency Pure Sine Wave Inverter Features:
1.Complete isolation-type inverter technology, noiseless output.




20KW off grid single phase inverter technical parameters
| Model | NB96-20KDZ | |
| DC input | Input rated voltage | 96VDC |
| Input rated current | 231.5A | |
| Input DC voltage allowing range | 80-124VDC | |
| AC Bypass | Allow input voltage range | 220 VAC ± 15% |
| Input rated current | 90.9A | |
| Bypass transfer time | ≤40ms(4ms optional) | |
| AC output | Rated capacity | 20KW |
| Output rated voltage and frequency | 220 VAC 50Hz / 60Hz | |
| Output rated current | 90.9A | |
| Output voltage accuracy | 220 VAC± 2% | |
| Output frequency accuracy | 50Hz / 60Hz ± 0.05% | |
| Wave | Pure sine wave (Isolation transformer) | |
| THD. | ≤3%(Linear load) | |
| Power factor (PF) | 1 | |
| Overload capacity | 120%,10minutes,200%,10 second | |
| Crest factor (CF) | 3:1 | |
| Inverter efficiency | >90% | |
| Working Environment | Dielectric strength | 1500VAC,1minute |
| Noise (1m) | ≤50dB | |
| Ambient temperature | -10ºC~+50ºC | |
| Humidity | 0~90%,No condensation | |
| Altitude | <3000m Higher than 3000m rated power should be reduced |
|
| Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |
| Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | |
| Ac charger | (optional) | |
| Battery, City grid (generator) priority | (optional) | |
| Size | 550*1060*1300mm | |
| Weight | 250kg | |
20KW off grid three phase inverter technical parameters
| Type | NB216-20KSZ | |
| DC input | Input rated voltage | 216VDC |
| Input rated current | 102.9A | |
| Input DC voltage allowing range | 180-280VDC | |
| AC bypass | Allow input voltage range | 380VAC± 15% VAC |
| Input rated current | 30.4A | |
| Bypass transfer time | ≤100ms(4ms optional) | |
| AC output | Rated capacity | 20KW |
| Output rated voltage and frequency | Three phase 380VAC,50Hz/60HZ | |
| Output rated current | 30.4A | |
| Output voltage accuracy | 380VAC ± 2% | |
| Output frequency accuracy | 50Hz ± 0.05% | |
| Wave | Pure sine wave (Isolation transformer) | |
| THD. | ≤3%(Linear load) | |
| Power factor (PF) | 1 | |
| Overload capacity | 120%,10 minutes | |
| Overcurrent capacity | 200%,10 seconds | |
| Crest factor (CF) | 3:1 | |
| Inverter efficiency | >92% | |
| Working Environment | Dielectric strength | 1500VAC,1minute |
| Noise (1m) | ≤50dB | |
| Ambient temperature | -10ºC~+50ºC | |
| Humidity | 0~90%, No condensation | |
| Altitude | <2000m Higher than 2000m rated power should be reduced |
|
| Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |
| Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | |
| Ac charger | (optional) | |
| Battery, City grid (generator) priority | (optional) | |
| Size | 550×1050×1340mm | |
| Weight | 220KG | |
50KW off grid three phase inverter technical parameters
| Type | NB384-50KSZ | |
| DC input | Input rated voltage | 384VDC |
| Input rated current | 144.7A | |
| Input DC voltage allowing range | 320-480VDC | |
| AC bypass | Allow input voltage range | 380VAC± 15% VAC |
| Input rated current | 76A | |
| Bypass transfer time | ≤100ms(4ms optional) | |
| AC output | Output rated power | 50KW |
| Output rated voltage and frequency | Three phase 380VAC,50HZ (Three phase four wire) |
|
| Output rated current | 76A | |
| Output voltage accuracy | 380VAC ± 2% | |
| Output frequency accuracy | 50Hz ± 0.05% | |
| Wave | Pure sine wave (Isolation transformer) | |
| THD. | ≤3%(Linear load) | |
| Power factor (PF) | 1 | |
| Overload capacity | 120%,10 minutes | |
| Overcurrent capacity | 200%,10 seconds | |
| Crest factor (CF) | 3:1 | |
| Inverter efficiency | >92% | |
| Working Environment | Dielectric strength | 1500VAC,1minute |
| Noise (1m) | ≤50dB | |
| Ambient temperature | -10ºC~+50ºC | |
| Humidity | 0~90%, No condensation | |
| Altitude | <2000m Higher than 2000m rated power should be reduced |
|
| Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |
| Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | |
| Ac charger | (optional) | |
| Battery, City grid (generator) priority | (optional) | |
| Size | 630*1310*1573mm | |
| Weight | 430KG | |