Customization: | Available |
---|---|
After-sales Service: | Provide |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
On grid wind turbine controller | WGMC50K380 | WGMC100K380 | WGMC200K380 |
Wind turbine input | |||
Power | 50KW | 100KW | 200KW |
Max. Control power | 100KW | 200KW | 400KW |
Rated voltage of wind turbine (AC) | 380V/400V | 380V/400V | 380V/400V |
Input voltage range | AC 0-600V | AC 0-600V | AC 0-600V |
DC 0-900V | DC 0-900V | DC 0-900V | |
Braking voltage (DC) | 550V±1% | 550V±1% | 550V±1% |
Braking time min | 10-20 min | ||
Manual control | Manual brake | ||
Automatic control function | Dump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake, * electromagnetic brake | ||
DC output parameters | |||
Output voltage range (DC) | 0-550V | 0-550V | 0-550V |
Constant voltage (DC) | 520V±1% | 520V±1% | 520V±1% |
On grid wind turbine inverter | DMWG50K | DMWG100K | DMWG200K |
Rated output power (AC) | 50KW | 100KW | 200KW |
Max. Output power (AC) | 55KW | 110KW | 220KW |
Input voltage rang (DC) | 0-800V | 0-800V | 0-800V |
MPPT Voltage range (DC) | 150V-700V | 150V-700V | 150V-700V |
Max. Input current (DC) | 114.6A | 229A | 458.3A |
Rated current | 104A | 208A | 416.7A |
THD Current harmonic | <3%(at rated power) | ||
Power factor | >0.99 | ||
Max. efficiency | 96% | ||
Allowable grid voltage range (AC) | 220V/380V/440V/480V (Three-phase)±20% | ||
Allowable grid frequency range | 50Hz/60Hz±10% | ||
Automatic operation conditions | DC input and power grid meet the requirements, and the inverter operates automatically | ||
Restart time after power failure | 5min (adjustable) | ||
General parameters | |||
Function | Rectification, DC output, output voltage control, output current control, Dump load control, control parameter setting, wind turbine curve setting | ||
Automatic protection | Control part: Over voltage protection, over current protection, reverse connection protection, lightning arrester Inverter part: Polarity reverse connection protection, short circuit protection, island effect protection, LVRT,overheat protection, overload protection, ground fault protection, etc |
||
Display | Touch screen, LCD | ||
Monitoring content | Fan voltage, current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speed | ||
Protection level | IP20(Indoor)IP65 (Outdoors) | ||
Telematics | RS485/USB/GPRS/WIFI/Ethernet (optional) | ||
Environment | Operating amb. Temp. & Hum -30-60°C,<90% no condensation | ||
Noise (1m) | <40dB | ||
Refrigeration mode | Forced air cooling | ||
Size / weight | |||
Controller size / weight | 500*500*900mm 56kg | 600*500*1200mm 107kg | 950*550*1700mm 150kg |
Dump load size / weight | 920*770*380mm 80kg | 920*770*380mm*2 150kg | 923*739*510mm*4 280kg |
Inverter size / weight | 750*600*1320mm 340kg | 1460*860*1820mm 1.4t | 1460*860*1820mm 1.6t |