On grid wind turbine controller | WGMC3K380 | WGMC5K380 | ||
Wind turbine input | ||||
Power | 3KW | 5KW | ||
Max. Control power | 6KW | 10KW | ||
Rated voltage of wind turbine (AC) | 380V | 380V | ||
Input voltage range | AC 0-600V | AC 0-600V | ||
DC 0-900V | DC 0-900V | |||
Braking voltage (DC) | 550V±1% | 550V±1% | ||
Braking time min | 10-20 min | |||
Manual control | Manual brake | |||
Automatic control function | Dump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake, * electromagnetic brake | |||
* PV. Input | ||||
Rated power (increased) | 3KWp | 5KWp | ||
Working voltage (DC) | 550V / 660V | 550V / 660V | ||
DC output parameters | ||||
Output voltage range (DC) | 0-550V | 0-550V | ||
Constant voltage (DC) | 520V±1% | 520V±1% | ||
On grid wind turbine inverter | DMWG3KTL | DMWG5KTL | ||
Rated output power (AC) | 3KW | 5KW | ||
Max. Output power (AC) | 3.3KW | 5.5KW | ||
Input voltage rang (DC) | 0-800V | 0-800V | ||
MPPT Voltage range (DC) | 150V-700V | 150V-700V | ||
Max. Input current (DC) | 6.8A | 11.2A | ||
Rated current | 6.2A | 10.2A | ||
THD Current harmonic | <3%(at rated power) | |||
Power factor | 0.8leading-1-0.8lagging, adjustable | |||
Max. efficiency | 98% | |||
Allowable grid voltage range (AC) | 220V/380V/440V/480V (Three-phase)±20% | |||
Allowable grid frequency range | 50Hz/60Hz±10% | |||
Automatic operation conditions | DC input and power grid meet the requirements, and the inverter operates automatically | |||
Restart time after power failure | 5min( adjustable) | |||
General parameters | ||||
Function | Rectification, DC output, output voltage control, output current control, Dump load control, control parameter setting, wind turbine curve setting | |||
Automatic protection | Control part: Over voltage protection, over current protection, reverse connection protection, lightning arrester Inverter part: Polarity reverse connection protection, short circuit protection, island effect protection, LVRT, overheat protection, overload protection, ground fault protection, etc |
|||
Display | Touch screen, LCD | |||
Monitoring content | Fan voltage, current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speed | |||
Protection level | IP20(Indoor)IP65 (Outdoors) | |||
Telematics | RS485/USB/GPRS/WIFI/Ethernet (optional) | |||
Environment | Operating amb. Temp. & Hum -30-60°C,<90% no condensation | |||
Noise (1m) | <40dB | |||
Refrigeration mode | Forced air cooling | |||
Size / weight | ||||
Controller size / weight | 360*230*480mm 17kg | 360*230*480mm 18kg | ||
Dump load size / weight | 400*400*250mm 12kg | 600*450*380mm 28kg | ||
Inverter size / weight | 550*225*770mm 49kg | 550*225*770mm 59kg |