Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 2751/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
1. using IGBT from Mitsubishi company as the power components
2. using American ATEMEL company microprocessor as figure controller
3. perfect protection and warning functions
4. circuit frame compact, Max. Efficiency≥94%
5. with wide input voltage range
6. RS232/485 communication, multi communication interface can be selected
7. big-screen English LCD, perfect display, interface-friendly
Model | NB220-20KSZ | NB110-20KSZ | NB96-20KSZ | NB48-20KSZ |
Rated Capacity | Output two phase 20KW | |||
Circuit Mode | IGBT/PWM | |||
DC Input | ||||
Input Rated Current | DC220V | DC110V | DC96V | DC48V |
Input DC voltage Range | DC180-300V | DC80-145V | DC75V-135V | DCC40V-60V |
Input Rated Current | 92.6A | 185A | 208.3A | 416.7A |
AC Output | ||||
Output Mode | Two phase three wires | |||
Output Wave | Pure Sine Wave | |||
Output Voltage | L1-N: 110Vac, L2-N: 110Vac, L1-L2: 220Vac | |||
Output Voltage accuracy | ±1% | |||
Output frequency | 50Hz | |||
Output frequency accuracy | ±0.01% | |||
Rated capacity | 25KVA | |||
Output rated power | 20KW | |||
Output Rated ampere | 90.9A | |||
Maximum output over current | 136.4A | |||
Maximum nominal current of loads | 90.9A | |||
Power factor | 0.8 | |||
Overload capacity | 120% 109A ,3 minutes,150% 136.4A,10 seconds | |||
Dynamic voltage transient range | 2%(0~100% load change) | |||
VTHD(Distortion) | THD<3%( non-linear load) | |||
Display Mode | ||||
Display Window | High accuracy four-in-one LED display | |||
Four digit voltmeter | Accuracy 0.1V | |||
Four digit ampere meter | Accuracy 0.1A | |||
Four digit frequency meter | Accuracy 0.1Hz | |||
Four digit power/power factor meter | Accuracy 0.1W | |||
System | ||||
System efficiency | Normal mode: 94% | |||
insulation resistance | DC> 500V 20MΩ | |||
insulating strength | (Input and output to ground)1800Vdc, leakage current<3.5mA, No-arcing for 1 min |
|||
Protection Class | IP22 | |||
Wiring method | Input and output wiring terminals,line bank | |||
Thermal methods | Transformer forced fan cooling | |||
Working temperature | -10ºC~+50ºC | |||
Relative humidity | 0-90%(No condensation) | |||
Noise(dB) | <65dB | |||
Protection Function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |||
Equipped with AC Bypass | Yes | |||
Product Size/Weight(L*W*H)mm | 550*480*950mm/135kg |
Model | NB220-30KSZ | NB110-30KSZ | NB96-30KSZ |
Rated Capacity | Output two phase 30KVA | ||
Circuit Mode | IGBT/PWM | ||
DC Input | |||
Input Rated Current | DC220V | DC110V | DC96V |
Input DC voltage Range | DC180-300V | DC80-145V | DC75V-135V |
Input Rated Current | 111A | 222A | 250A |
AC Output | |||
Output Mode | Two phase three wires | ||
Output Wave | Pure Sine Wave | ||
Output Voltage | L1-N: 110Vac, L2-N: 110Vac, L1-L2: 220Vac | ||
Output Voltage accuracy | ±1% | ||
Output frequency | 50Hz | ||
Output frequency accuracy | ±0.01% | ||
Rated capacity | 30KVA | ||
Output rated power | 24KW | ||
Output Rated ampere | 109A | ||
Maximum output over current | 163.5A | ||
Maximum nominal current of loads | 109A | ||
Power factor | 0.8 | ||
Overload capacity | 120% 130.8A ,3 minutes,150% 163.5A,10 seconds | ||
Dynamic voltage transient range | 2%(0~100% load change) | ||
VTHD(Distortion) | THD<3%( non-linear load) | ||
Display Mode | |||
Display Window | High accuracy four-in-one LED display | ||
Four digit voltmeter | Accuracy 0.1V | ||
Four digit ampere meter | Accuracy 0.1A | ||
Four digit frequency meter | Accuracy 0.1Hz | ||
Four digit power/power factor meter | Accuracy 0.1W | ||
System | |||
System efficiency | Normal mode: 94% | ||
insulation resistance | DC> 500V 20MΩ | ||
insulating strength | (Input and output to ground)1800Vdc, leakage current<3.5mA, No-arcing for 1 min |
||
Protection Class | IP22 | ||
Wiring method | Input and output wiring terminals,line bank | ||
Thermal methods | Transformer forced fan cooling | ||
Working temperature | -10ºC~+50ºC | ||
Relative humidity | 0-90%(No condensation) | ||
Noise(dB) | <65dB | ||
Protection Function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
Equipped with AC Bypass | Yes | ||
Product Size/Weight(L*W*H)mm | 550*480*950mm/135kg |
Model | NB220-50KSZ | NB384-50KSZ |
Rated Capacity | Output two phase 50KVA | |
Circuit Mode | IGBT/PWM | |
DC Input | ||
Input Rated Current | DC220V | DC384V |
Input DC voltage Range | DC180-300V | DC300-490V |
Input Rated Current | 185A | 104A |
AC Output | ||
Output Mode | Two phase three wires | |
Output Wave | Pure Sine Wave | |
Output Voltage | L1-N: 110Vac, L2-N: 110Vac, L1-L2: 220Vac | |
Output Voltage accuracy | ±1% | |
Output frequency | 50Hz | |
Output frequency accuracy | ±0.01% | |
Rated capacity | 50KVA | |
Output rated power | 40KW | |
Output Rated ampere | 182A | |
Maximum output over current | 273A | |
Maximum nominal current of loads | 182A | |
Power factor | 0.8 | |
Overload capacity | 120% 218.4A ,3 minutes,150% 273A,10 seconds | |
Dynamic voltage transient range | 2%(0~100% load change) | |
VTHD(Distortion) | THD<3%( non-linear load) | |
Display Mode | ||
Display Window | High accuracy four-in-one LED display | |
Four digit voltmeter | Accuracy 0.1V | |
Four digit ampere meter | Accuracy 0.1A | |
Four digit frequency meter | Accuracy 0.1Hz | |
Four digit power/power factor meter | Accuracy 0.1W | |
System | ||
System efficiency | Normal mode: 94% | |
insulation resistance | DC> 500V 20MΩ | |
insulating strength | (Input and output to ground)1800Vdc, leakage current<3.5mA, No-arcing for 1 min |
|
Protection Class | IP22 | |
Wiring method | Input and output wiring terminals,line bank | |
Thermal methods | Transformer forced fan cooling | |
Working temperature | -10ºC~+50ºC | |
Relative humidity | 0-90%(No condensation) | |
Noise(dB) | <65dB | |
Protection Function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |
Equipped with AC Bypass | Yes | |
Product Size/Weight(L*W*H)mm | 550*480*950mm/200kg |