| Customization: | Available |
|---|---|
| Type: | Combiner Box |
| Structure: | Protection |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

| Model | DM-CB5 |
| Basic | |
| Max.PV Array Voltage | 1000V |
| Max. PV Array parallel Inputs | 5 |
| Rated fuse current(replaceable) | 15A |
| Allowable input current | 10A |
| Output Circuit Breaker | 60A |
| Max. Output current | 50A |
| Diameter of wire of input PV array | 2.5 mm² |
| Diameter of wire of output PV array | 12 mm² |
| Diameter of wire for ground | 10 mm² |
| PV dedicated SPD | Yes |
| Anti-reverse | Yes |
| IP | IP65 |
| Size(mm) | 560*500*195mm |
| Weight | 16KG |
| Environment | |
| Normal working temperature/humidity | -25ºC-70ºC,humidity 95% No Condensation,No corrosive gas |
| Altitude(m) | <2000m |
| Alarm | DC Arc fault state, voltage alarm, current alarm, temperature alarm etc |
| Optional | |
| Communication Interface | RS485/Modbus-RTU Protocol |
| Current monitor for each string | Yes |
| Signal Arrester | Yes |
| Model | DM-CB08 |
| Basic | |
| Max.PV Array Voltage | 1000V |
| Max. PV Array parallel Inputs | 8 |
| Rated fuse current(replaceable) | 15A |
| Allowable input current | 10A |
| Output Circuit Breaker | 100A |
| Max. Output current | 80A |
| Diameter of wire of input PV array | 2.5 mm² |
| Diameter of wire of output PV array | 16 mm² |
| Diameter of wire for ground | 10 mm² |
| PV dedicated SPD | Yes |
| Anti-reverse | Yes |
| IP | IP65 |
| Size(mm) | 560*500*195mm |
| Weight | 18KG |
| Environment | |
| Normal working temperature/humidity | -40ºC-70ºC,humidity 95% No Condensation,No corrosive gas |
| Altitude(m) | <2000m |
| Alarm | DC Arc fault state, voltage alarm, current alarm, temperature alarm etc |
| Optional | |
| Communication Interface | RS485/Modbus-RTU Protocol |
| Current monitor for each string | Yes |
| Signal Arrester | Yes |
| Model | DM-CB12 |
| Basic | |
| Max.PV Array Voltage | 1000V |
| Max. PV Array parallel Inputs | 12 |
| Rated fuse current(replaceable) | 15A |
| Allowable input current | 10A |
| Output Circuit Breaker | 150A |
| Max. Output current | 120A |
| Diameter of wire of input PV array | 2.5 mm² |
| Diameter of wire of output PV array | 24 mm² |
| Diameter of wire for ground | 10 mm² |
| PV dedicated SPD | Yes |
| Anti-reverse | Yes |
| IP | IP65 |
| Size(mm) | 670*620*240mm |
| Weight | 18KG |
| Environment | |
| Normal working temperature/humidity | -40ºC-70ºC,humidity 95% No Condensation,No corrosive gas |
| Altitude(m) | <2000m |
| Alarm | DC Arc fault state, voltage alarm, current alarm, temperature alarm etc |
| Optional | |
| Communication Interface | RS485/Modbus-RTU Protocol |
| Current monitor for each string | Yes |
| Signal Arrester | Yes |