Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 1085/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
1. using IGBT from Mitsubishi company as the power components
2. using American ATEMEL company microprocessor as figure controller
3. perfect protection and warning functions
4. circuit frame compact, Max. Efficiency≥94%
5. with wide input voltage range
6. RS232/485 communication, multi communication interface can be selected
7. big-screen English LCD, perfect display, interface-friendly
Model | NB96-3KSZ | NB48-3KSZ |
Rated Capacity | Output two phase 3KW | Output two phase 3KW |
Circuit Mode | IGBT/PWM | |
DC Input | ||
Input Rated Current | DC96V | DC48V |
Input DC voltage Range | DC75V-135V | DC40V-60V |
Input Rated Current | 31.25A | 62.5A |
AC Output | ||
Output Mode | Two phase three wires | |
Output Wave | Pure Sine Wave | |
Output Voltage | L1-N: 110Vac, L2-N: 110Vac, L1-L2: 220Vac | |
Output Voltage accuracy | ±1% | |
Output frequency | 50Hz | |
Output frequency accuracy | ±0.01% | |
Rated capacity | 3.75KVA | 3.75KVA |
Output rated power | 3KW | 3KW |
Output Rated ampere | 13.6A | 13.6A |
Maximum output over current | 20.4A | 20.4A |
Maximum nominal current of loads | 13.6A | |
Power factor | 0.8 | |
Overload capacity | 120% 16.3A ,3 minutes,150% 20.4A,10 seconds | |
Dynamic voltage transient range | 2%(0~100% load change) | |
VTHD(Distortion) | THD<3%( non-linear load) | |
Display Mode | ||
Display Window | High accuracy four-in-one LED display | |
Four digit voltmeter | Accuracy 0.1V | |
Four digit ampere meter | Accuracy 0.1A | |
Four digit frequency meter | Accuracy 0.1Hz | |
Four digit power/power factor meter | Accuracy 0.1W | |
System | ||
System efficiency | Normal mode: 94% | |
insulation resistance | DC> 500V 20MΩ | |
insulating strength | (Input and output to ground)1800Vdc, leakage current<3.5mA, No-arcing for 1 min |
|
Protection Class | IP22 | |
Wiring method | Input and output wiring terminals,line bank | |
Thermal methods | Transformer forced fan cooling | |
Working temperature | -10ºC~+50ºC | |
Relative humidity | 0-90%(No condensation) | |
Noise(dB) | <65dB | |
Protection Function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |
Equipped with AC Bypass | Yes | |
Product Size(L*W*H)mm | 550*480*950 | |
Product Weight(kg) | 95kg |
Model | NB220-5KSZ | NB110-5KSZ | NB96-5KSZ | NB48-5KSZ |
Rated Capacity | Output two phase 5KW | |||
Circuit Mode | IGBT/PWM | |||
DC Input | ||||
Input Rated Current | DC220V | DC110V | DC96V | DC48V |
Input DC voltage Range | DC180-300V | DC80-145V | DC75V-135V | DC40V-60V |
Input Rated Current | 23A | 46A | 52A | 104A |
AC Output | ||||
Output Mode | Two phase three wires | |||
Output Wave | Pure Sine Wave | |||
Output Voltage | L1-N: 110Vac, L2-N: 110Vac, L1-L2: 220Vac | |||
Output Voltage accuracy | ±1% | |||
Output frequency | 50Hz | |||
Output frequency accuracy | ±0.01% | |||
Rated capacity | 6.25KVA | |||
Output rated power | 5KW | |||
Output Rated ampere | 22.7A | |||
Maximum output over current | 34A | |||
Maximum nominal current of loads | 22.7A | |||
Power factor | 0.8 | |||
Overload capacity | 120% 27.2A ,3 minutes,150% 34A,10 seconds | |||
Dynamic voltage transient range | 2%(0~100% load change) | |||
VTHD(Distortion) | THD<3%( non-linear load) | |||
Display Mode | ||||
Display Window | High accuracy four-in-one LED display | |||
Four digit voltmeter | Accuracy 0.1V | |||
Four digit ampere meter | Accuracy 0.1A | |||
Four digit frequency meter | Accuracy 0.1Hz | |||
Four digit power/power factor meter | Accuracy 0.1W | |||
System | ||||
System efficiency | Normal mode: 94% | |||
insulation resistance | DC> 500V 20MΩ | |||
insulating strength | (Input and output to ground)1800Vdc, leakage current<3.5mA, No-arcing for 1 min |
|||
Protection Class | IP22 | |||
Wiring method | Input and output wiring terminals,line bank | |||
Thermal methods | Transformer forced fan cooling | |||
Working temperature | -10ºC~+50ºC | |||
Relative humidity | 0-90%(No condensation) | |||
Noise(dB) | <65dB | |||
Protection Function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |||
Equipped with AC Bypass | Yes | |||
Product Size(L*W*H)mm | 550*480*950 | |||
Product Weight(kg) | 95kg |
Model | NB220-10KSZ | NB110-10KSZ | NB96-10KSZ | NB48-10KSZ |
Rated Capacity | Output two phase 10KW | |||
Circuit Mode | IGBT/PWM | |||
DC Input | ||||
Input Rated Current | DC220V | DC110V | DC96V | DC48V |
Input DC voltage Range | DC180-300V | DC80-145V | DC75V-135V | DCC40V-60V |
Input Rated Current | 46.3A | 92.6A | 104A | 208.3A |
AC Output | ||||
Output Mode | Two phase three wires | |||
Output Wave | Pure Sine Wave | |||
Output Voltage | L1-N: 110Vac, L2-N: 110Vac, L1-L2: 220Vac | |||
Output Voltage accuracy | ±1% | |||
Output frequency | 50Hz | |||
Output frequency accuracy | ±0.01% | |||
Rated capacity | 12.5KVA | |||
Output rated power | 10KW | |||
Output Rated ampere | 45.5A | |||
Maximum output over current | 68A | |||
Maximum nominal current of loads | 45.5A | |||
Power factor | 0.8 | |||
Overload capacity | 120% 54.6A ,3 minutes,150% 68A,10 seconds | |||
Dynamic voltage transient range | 2%(0~100% load change) | |||
VTHD(Distortion) | THD<3%( non-linear load) | |||
Display Mode | ||||
Display Window | High accuracy four-in-one LED display | |||
Four digit voltmeter | Accuracy 0.1V | |||
Four digit ampere meter | Accuracy 0.1A | |||
Four digit frequency meter | Accuracy 0.1Hz | |||
Four digit power/power factor meter | Accuracy 0.1W | |||
System | ||||
System efficiency | Normal mode: 94% | |||
insulation resistance | DC> 500V 20MΩ | |||
insulating strength | (Input and output to ground)1800Vdc, leakage current<3.5mA, No-arcing for 1 min |
|||
Protection Class | IP22 | |||
Wiring method | Input and output wiring terminals,line bank | |||
Thermal methods | Transformer forced fan cooling | |||
Working temperature | -10ºC~+50ºC | |||
Relative humidity | 0-90%(No condensation) | |||
Noise(dB) | <65dB | |||
Protection Function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |||
Equipped with AC Bypass | Yes | |||
Product Size(L*W*H)mm | 550*480*950 | |||
Product Weight(kg) | 135kg |