Customization: | Available |
---|---|
Nature of Source Flow: | Active Inverter |
Certification: | ISO9001, CE |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | DMWG-50KS |
Isolation | Frequency transformer isolation |
Maximum DC input power | 55KWp |
Maximum input voltage allows the fan | 800Vdc |
Maximum Power Point Tracking (MPPT) range | 450Vdc-780Vdc |
Nominal AC output power | 50KW |
Max. AC output power | 55KW |
THD of AC current | <3%(Rated power) |
Power factor | >0.99 |
Max. efficiency | 94% |
Euro efficiency | 92% |
Output rating voltage | 380Vac 50HZ |
Allowed Grid Voltage Range | 310~450Vac |
Allowed Grid Frequency Range | 47.5~51.5Hz |
Internal power consumption an night | <10W |
Automatically put into operation conditions | DC input and power to meet the requirements, the inverter automatically run |
Automatic restart after power failure time | 2min |
Protection | Reverse polarity, short circuit, island, overheating and overload etc |
Comm. interfaces | RS485(Modbus Agreement) |
Operating Temp. | -25ºC~+60ºC |
Relative humidity | 0~90%,Non-condensing |
Altitude(m) | 6000 meters (over 2000 m with derating required) |
Cooling method | Forced air cooling |
Noise | ≤60dB |
Protection degree | IP20(indoor) |
Communications monitoring | Inverter via RS485 communication for start-stop control and routine data monitoring |
Type | FKJ-GT-50KW |
Wind turbine rated power | 50KW |
Wind turbine Max. power | 100KW |
Function | Rectifier,charge, control |
Display mode | LED |
Display content | DC output voltage, |
PWM constant voltage | ≥650dc |
wind turbine 3-phase dump load voltage1 | 670±5Vdc |
three-phase dump load 1 delay time | 12-20 min |
wind turbine 3-phase dump load voltage2 | 680±5Vdc |
three-phase dump load 2 delay time | 12-20 min |
wind turbine 3-phase dump load voltage3 | 700±5Vdc |
three-phase dump load 3 delay time | 12-20 min |
Low-voltage | ≤200Vdc |
PWM dump load fuse | 63A |
Fuse of DC output | 100A |
Self-provided connecting wire of the PWM dump load (mm²) | >10mm² |
Self-provided connecting wire of the dump load 1(mm²) | >10mm² |
Self-provided connecting wire of the dump load 2(mm²) | >10mm² |
Self-provided connecting wire of the dump load 3(mm²) | >10mm² |
Work environment temperature | -30-60°C |
Relative humidity | <90% No condensation |
Noise (1m) | <40dB |
Degree of protection | IP20(Indoor) |
Cooling method | Forced air cooling |
*Temperature compensation(optional) | -4mv/°C/2V,-35°C~+80°C, Accuracy:±1°C |
Size of the controller (mm) | 690*590*1300 mm |
Weight of the controller | 120Kg |
Size of the dump load (mm) | 800*580*1300mm 760*520*1200mm(2pcs) |
Weight of the dump load | 128Kg |