Technical Parameters of the Grid-tie Wind Turbine Controller 12KW
Company Name: Jinan Deming Power Equipment Co., Ltd
Product Name: Factory Price Grid Connected Wind Charge Controller
Keywords: Wind Charge Controller, Grid Connected Wind Controller, Grid Tie Wind Charge Controller, Factory Price Wind Charge Controller, On Grid Wind Charge Controller, Grid Tie Wind Turbine Controller, Grid Connected Wind Generator Controller, On Grid Wind Solar Charge Controller, MPPT On Grid Wind Charge Controller, Grid Tie Wind Solar Hybrid Charge Controller, Grid Tie Wind Generator Controller, On Grid Controller, Grid Connected Controller, Wind Grid Tie Controller, On Grid Wind Solar Controller, On Grid Wind Turbine Charge Controller, Grid Connected Wind Turbine Charge Controller, On Grid Wind Generator Charge Controller, Grid Tie Wind Solar Charge Controller, Grid Tie Wind Turbine Charge Controller, On Grid Wind Solar Hybrid Charge Controller, MPPT On Grid Controller, Grid Connected Wind Generator Charge Controller, On Grid Wind Solar Hybrid Charge Controller, Factory Price Wind Turbine Charge Controller, Grid Tie Wind Solar Controller, On Grid Wind Hybrid Charge Controller, Grid Connected Wind Solar Charge Controller, MPPT On Grid Wind Solar Controller, Wind Charge Controller for On Grid Wind Turbine, Factory Price Grid Connected Controller
Type |
FKJ-GT-12KW |
Wind turbine rated power |
12KW |
Wind turbine Max. power |
24KW |
Function |
Rectifier, control, dc output |
Display mode |
LCD |
Display content |
Wind turbine voltage, wind turbine current, wind turbine power, DC output voltage, output current, output power |
PWM constant voltage |
≥550dc |
3-phase dump load voltage of the wind turbine |
580±5Vdc |
Time-lapse of the wind turbine 3-phase dump load |
12-20 min |
Low-voltage |
≤200Vdc |
PWM dump load fuse |
30A |
Fuse of DC output |
40A |
Work environment temperature |
-30-60°C |
Relative humidity |
<90% No condensation |
Noise (1m) |
<40dB |
Degree of protection |
IP20(Indoor) |
Cooling method |
Forced air cooling |
*Communication interface (optional) |
RS485/USB/GPRS/Ethernet |
*Temperature compensation(optional) |
-4mv/°C/2V,-35°C~+80°C,
Accuracy:±1°C |
Size of the controller |
575*430*320 mm |
Weight of the controller |
20Kg |
Size of the dump load |
670*520*445 mm |
Weight of the dump load |
27Kg |