• 10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter
  • 10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter
  • 10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter
  • 10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter
  • 10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter
  • 10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter

10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter

Nature of Source Flow: Active Inverter
Certification: ISO9001, CE
Output Power: 10kw
Grid Type: Grid Inverter
Output Type: Triple
Circuit Topologies: Full-Bridge Type
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
DMPCS-10KSTL
Nature of Wave String
Sine Wave Inverter
Type
DC/AC Inverters
Transport Package
Wooden Box
Trademark
Deming
Origin
Shandong
HS Code
8504403090
Production Capacity
100/Week

Product Description

-------------------------------------------------------------------------------------------------------------------
Power Conversion System( Bidirectional Inverter Performance )
Characteristics And Specifications


The power conversion system can control the charging and discharging process of the battery, conduct AC/DC conversion, and directly supply power to AC loads without power grid. PCS is composed of DC/AC bidirectional converter, control unit, etc. The PCS controller receives background control commands through communication, controls the converter to charge or discharge the battery according to the symbol and size of the power command, and realizes the regulation of the active power and reactive power of the grid. The PCS controller communicates with the BMS through the CAN interface to obtain the status information of the battery pack, which can realize the protetive charging and discharging of the battery and ensure the safe operation of the battery.

-------------------------------------------------------------------------------------------------------------------
Functions And Applications Of PCS

· Specially designed for smart grid and smart micro-grid, accepting grid dispatching, peak cutting  and valley filling.
· It has a wide application range, can connect with different energy storage batteries such as lead-acid battery, lithium battery, super capacitor and vanadium battery, etc.
· Bidirectional inverter, a variety of battery charging and discharging modes optional.
· It has the function of setting working mode in time period, can set reasonable working mode  according to the characteristics of local power grid.
· Integrated EMS management system, in the solar energy storage system, can set the priority of  solar, battery and grid (optional).
· It has two operation modes: grid-conned (charge-discharge)  operation and independent isolated network operation.It can control active power and reactive power output according to the instruction of the grid dispatching department,and has four-quadrant full capacity operation.
· RS485, CAN bus and other communication interface are optional, standard MODBUS_ RTU com- munication protocol, remote monitoring:RS485,CAN.

-------------------------------------------------------------------------------------------------------------------
PCS Schematic Diagram
10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter
                                                                                             (Charge and discharge system of PSC)

The system consists of battery, PCS and grid, which is the most basic application scenario. It is often used for peak-load shifting. There are two operating modes, manual and automatic (setting charging and discharging time and power).
 
 
10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter
                                             Solar energy storage system(PV charging controller and PCS separated)
 
The PCS in this system, is built-in MPPT solar charging module, integrated EMS management system.It can realize that the solar panels provide power to the load preferentially through PCS, and the excess electricity is used to charge the battery. When the battery is fully charged, the electricity from the solar panels is fed into the grid through PCS.

·When the solar panel power is insufficient, the battery is discharged to supply power to the load.
·When the battery power is insufficient to support the load, the battery and the grid power supply the load at the same time. As the battery power varies from 100% to the battery under voltage protection value (can be set), the corresponding grid power supplies the load from 0% to 100%.
·The PCS has a load port. This port has the UPS function to meet the load uninterrupted power supply.

10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter                                                                   Solar energy storage system(PV charging controller and PCS separated)
10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter
                                                                                          New energy intelligent micro grid system

This system is composed of photovoltaic grid-connected system, wind turbine grid-connected system, PCS, energy storage battery and grid.
PCS integrates EMS management system, which can realize the power generated by solar panel and wind turbine to charge the battery first. It can also be used with intelligent micro grid by setting the charging and discharging time and power.


-------------------------------------------------------------------------------------------------------------------
System Features
·Specially designed for smart grid and smart micragrid to accept power grid dispatching.
·Meet the requirements of lead acid battery, lithium battery, super capacitor, vanadium battery and other different forms of energy storage, and has a wide range of applications; Bidirectional inverter, constant power, current, voltage charge and discharge and other battery charge and discharge modes can be selected.
·With time period working mode setting function, set up reasonable working mode according to local power network characteristics.

·Two AC interfaces, i.e. mains interface and load interface, to realize grid connected operation and independent isolated grid operation.
·Perfect islanding detection and mode switching of parallel and off grid, when the power supply is suddenly cut off the PCS can automatically and seamlessly switch to the off grid working mode separate from the grid and establish a micro grid to operate independently.
·RS485, Ethernet, can bus and other communication interfaces are optional to realize remote monitoring.
·The smart grid master control system can be interconnected with on grid solar inverter,on grid wind power system, tidal power generation system, diesel generator and other energy modes to form a hybrid energy smart grid, which can realize a variety of networking modes.

-------------------------------------------------------------------------------------------------------------------
Performance characteristics
(1)The 32-bit DSP (Digital Processor TI 2812) +ARM (Touch Screen Master Chip) platform is used for touch screen display and operation, which facilitates field operation and parameter setup. The core driver of DSP control and ARM realize peripheral functions such as display and communication to improve power reliability.
(2)Support RS485, WiFi, GPRS, Ethernet communication, satisfy customer remote monitoring and other functions; can display AC and DC side voltage, current, operation mode, operation status, fault information, and can upload related data to the Internet of Things platform through the communication interface, and can start and stop power supply, parameter settings and other operations through the computer or mobile phone;
(3)Adopt three-phase four-bridge arm structure, which can carry 100% unbalanced load;;
(4)Designed for smart grids and smart microgrids, accept grid dispatching, cut peaks and fill valleys;

(5)Meets the access of lead-acid accumulator, lithium power, super capacitor, vanadium battery and other different energy storage forms, and has a wide range of applications.
10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter
 
 
10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter
 
 
10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter
 
 
10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter
 
 
10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter
 
10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter
10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter
 
AC Side parameters
AC wiring mode Three phase four wire
Rated output power 10KW 20KW 30KW
Output overload capacity 11KW 22KW 33KW
Rated grid voltage(AC) 220V / 380V / 440V 220V / 380V / 440V 220V / 380V / 440V
Grid voltage range ±20% ±20% ±20%
Rated grid frequency 50Hz / 60Hz 50Hz / 60Hz 50Hz / 60Hz
Grid frequency range ±10% ±10% ±10%
Rated power(THD) <3% (Standard grid)
Power factor 0.8-1-0.8,   0.8leading-1-0.8lagging, adjustable
DC Battery Side Parameters
Maximum DC power 11KW 22KW 33KW
DC voltage range Vdc 200-700Vdc 200-700Vdc 200-700Vdc

Recommended battery nominal voltage
240V / 384V / 420V / 480V
Rated charge current 50A 100A 150A
 Max input current   55A 110A 165A
/ Voltage/Steady flow accuracy ±1% ±1% ±1%
DC current ripple <1% Irms <1% Irms <1% Irms
* DC Solar Panels Side Parameters
Solar Panels Power 10KWp 20KWp 30KWp
Solar Panel Vmp ≥290V / ≥470V / ≥500V / ≥580V
Solar Maximum Voc <850V <850V <850V
PV Rated charging current 42A 26A 24A 21A 83A 52A 48A 42A 125A 78A 72A 63A
Independent inverter mode
Rated output voltage(AC) 220V / 380V / 440V±1%
Output voltage distortion <3% ( resistive load)
Rated output frequency 50Hz / 60Hz ±1%
Voltage transition range <10% (Resistance load 0% <=>100%)
System Parameters
Operating Mode ,,*EMS Manual Mode,Auto Mode,*EMS Mode
Charging and discharging mode ,, Constant current, Constant voltage, Constant power
On/off grid switching time 0ms
Max. conversion efficiency 97%  /  95%( Include isolation transformer)
Noise <60dB
Protection Degree IP21
Working Temperature -25ºC~+45ºC
Cooling method Air cooling
Working humidity 0~95%
Working altitude ≤6000m, 2000m(Reduced usage for more than 2000m)
Emergency stop Yes (via emergency stop button)
Display Touch screen
Communication mode RS485,WIFI,GPRS,Ethernet (Modbus protocol)
Dimensions 500*500*900mm   550*550*1000mm 550*550*1100mm
Weight 65KG 85KG 95KG
 
 
10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter
 
 
 
10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter
 
 
10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter
 
 
10kw on Grid Inverter with AC Charger and PCS for Solar Hybrid Inverter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now