Customization: | Available |
---|---|
Nature of Source Flow: | Passive inverter |
Certification: | ISO9001, CE |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Our energy system offers bi-directional flow, allowing for both discharge from the battery side to the DC grid and charge from the DC grid side to the battery. With fully automatic protection functions, including overheating, overload, short circuit, and overcurrent, our system ensures safety and reliability.
Featuring original imported power devices and a fully digital circuit design, our system utilizes industrial-grade chips that can operate in cold, high temperature, and humid environments. The main circuit incorporates a DSP chip produced by TI of America, Infineon IGBT module, and Infineon movement for driving and protection.
Our system provides automatic synchronization with the grid, resulting in low current harmonic content and no pollution or impact on the grid. The closed-loop control of grid-connected current allows for controllable and adjustable output. With a wide input voltage range, our system is suitable for various occasions.
Equipped with a comprehensive power protection scheme and self-test and protection function, our system will stop working in case of system failure. The compact circuit structure ensures maximum efficiency of ≥ 96%. The protection level can be customized according to the user's needs.
Additionally, our system offers an Ethernet interface and standard Modbus TCP communication protocol for seamless connectivity.
Rated power |
250KW |
LV rated current |
358A MAX:716A |
LV voltage range |
600-700Vdc |
Ripples coefficient |
HV side < 1% F.S. LV side < 2% F.S. |
Control accuracy |
< 1%(Remote and local control, @ full load) |
Max. efficiency |
96% @ full load |
Switching frequency on IGBTs |
6kHz |
HV Voltage range |
900-1314Vdc |
Dynamic response time |
<2ms |
Protection function |
Reverse polarity, overheating, overload, overvoltage, overcurrent, undervoltage, etc |
Display |
Touch screen |
Time propagation |
200ms |
Communication interface and protocol |
Modbus_ TCP, RJ45 Modbus_ RTU, RS485 |
RS485 interface number |
one |
Working temperature |
-10ºC to +50ºC |
Relative humidity |
0~95%,No condensation |
Altitude |
≤2000m(More than 2000 meters need to be reduced) |
Cooling mode |
Air cooling |
Noise |
≤65dB |
Emergency stop switch |
yes |
Level of protection |
IP55 |
System electrical input |
AC230V 50/60Hz 1000W |
Rated power | 500KW |
LV rated current | 667A MAX:734A |
LV voltage range | 680-790Vdc |
Ripples coefficient | HV side < 1% F.S. |
LV side < 2% F.S. | |
Control accuracy | < 1%(Remote and local control, @ full load) |
Max. efficiency | 98% @ full load |
Switching frequency on IGBTs | 6kHz |
HV Voltage range | 900-1314Vdc |
Dynamic response time | <2ms |
Protection function | Reverse polarity, overheating, overload, overvoltage, overcurrent, undervoltage, etc |
Display | Touch screen |
Time propagation | 200ms |
Communication interface and protocol | Modbus_ TCP, RJ45 Modbus_ RTU, RS485 |
RS485 interface number | one |
Working temperature | -10ºC to +50ºC |
Relative humidity | 0~95%,No condensation |
Altitude | ≤2000m(More than 2000 meters need to be reduced) |
Cooling mode | Air cooling |
Noise | ≤65dB |
Emergency stop switch | yes |
Level of protection | IP55 |
System electrical input | AC220V 1000W |