Customization: | Available |
---|---|
After-sales Service: | Provide |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 1100/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Type | FKJ-GT1.5KW | FKJ-GT2KW | FKJ-GT3KW |
Wind turbine rated power | 1.5KW | 2KW | 3KW |
Wind turbine Max. power | 3KW | 4KW | 6KW |
Wind turbine rated voltage | AC220V | AC220V | AC220V |
Solar panels power (optional) | 300W | 600W | 900W |
Function | Rectifier,control,DC output | ||
Automatic protection function | Over voltage protection, network electric cut off protection, regulated supply output, arrester | ||
Manual function | Manual brake, reset, emergency switch | ||
Display mode | LCD | ||
Display content | Wind turbine voltage, current, power; Solar voltage, current, power; DC output voltage, DC output current, DC output power, total power. | ||
PWM constant voltage | ≥320dc | ≥320dc | ≥320dc |
Wind turbine 3-phase dump load voltage | 350±5Vdc | 350±5Vdc | 350±5Vdc |
Wind turbine 3-phase dump load time-lapse | 12-20 min | 12-20 min | 12-20 min |
Solar panels fuse | 2A | 3A | 4A |
PWM dump load fuse | 10A | 10A | 16A |
Fuse of DC output | 16A | 16A | 20A |
Work environment temperature | -30-60°C | ||
Relative humidity | <90% No condensation | ||
Noise (1m) | <40dB | ||
Degree of protection | IP20 (Indoor) IP65 (Outdoors) | ||
Cooling method | Forced air cooling | ||
Communication interface (optional) | RS485/USB/GPRS/WIFI/Ethernet | ||
Temperature compensation (optional) | -4mv/°C/2V,-35°C~+80°C,Accuracy:±1°C | ||
Size of the controller (mm) | 510*360*240 | 510*360*240 | 510*360*240 |
Weight of the controller | 15Kg | 17Kg | 17Kg |
Size of the dump load (mm) | 410*360*120 | 410*360*120 | 400*410*250 |
Weight of the dump load | 7Kg | 9Kg | 13Kg |
Technical Parameters of the On Grid Wind Turbine (wind solar hybrid) Controller 5KW-10KW
Type | FKJ-GT5KW | FKJ-GT5KW | FKJ-GT10KW | |
Wind turbine rated power | 5KW | 5KW | 10KW | |
Wind turbine Max. power | 10KW | 10KW | 20KW | |
Wind turbine rated voltage | AC220V | AC380-400V | AC380-400V | |
Solar panels power(optional) | 1.5KW | 1.5KW | 3KW | |
Function | Rectifier,control,DC output | |||
Automatic protection function | Over voltage protection, network electric cut off protection, regulated supply output, arrester | |||
Manual function | Manual brake, reset, emergency switch | |||
Display mode | LCD | |||
Display content | Wind turbine voltage, current, power; Solar voltage, current, power; DC output voltage, DC output current, DC output power, total power. | |||
PWM constant voltage | ≥320dc | ≥520dc | ≥520dc | |
Wind turbine 3-phase dump load voltage | 350±5Vdc | 540±5Vdc | 540±5Vdc | |
Wind turbine 3-phase dump load time-lapse | 12-20 min | 12-20 min | 12-20 min | |
Solar panels fuse | 5A | 5A | 8A | |
PWM dump load fuse | 25A | 16A | 32A | |
Fuse of DC output | 32A | 20A | 40A | |
Work environment temperature | -30-60°C | |||
Relative humidity | <90% No condensation | |||
Noise (1m) | <40dB | |||
Degree of protection | IP20(Indoor) IP65 (Outdoors) | |||
Cooling method | Forced air cooling | |||
Communication interface (optional) | RS485/USB/GPRS/WIFI/Ethernet | |||
Temperature compensation(optional) | -4mv/°C/2V,-35°C~+80°C,Accuracy:±1°C | |||
Size of the controller (mm) | 510*360*240 | 510*360*240 | 580*400*240 | |
Weight of the controller | 18Kg | 18Kg | 23Kg | |
Size of the dump load (mm) | 600*450*380 | 600*450*380 | 690*450*530 | |
Weight of the dump load | 28Kg | 28Kg | 35Kg | |
*Above parameter only for reference
1. Could be custom made to user specifications. 2, Could have solar power control subject to user demand.