FKJ-GT (Grid-tie) model On grid Wind Turbine Controller Product Characteristics



Technical Parameters of the On Grid Wind Turbine (wind solar hybrid) Controller 1.5KW-3KW
| Type | FKJ-GT1.5KW | FKJ-GT2KW | FKJ-GT3KW |
| Wind turbine rated power | 1.5KW | 2KW | 3KW |
| Wind turbine Max. power | 3KW | 4KW | 6KW |
| Wind turbine rated voltage | AC220V | AC220V | AC220V |
| Solar panels power (optional) | 300W | 600W | 900W |
| Function | Rectifier,control,DC output | ||
| Automatic protection function | Over voltage protection, network electric cut off protection, regulated supply output, arrester | ||
| Manual function | Manual brake, reset, emergency switch | ||
| Display mode | LCD | ||
| Display content | Wind turbine voltage, current, power; Solar voltage, current, power; DC output voltage, DC output current, DC output power, total power. | ||
| PWM constant voltage | ≥320dc | ≥320dc | ≥320dc |
| Wind turbine 3-phase dump load voltage | 350±5Vdc | 350±5Vdc | 350±5Vdc |
| Wind turbine 3-phase dump load time-lapse | 12-20 min | 12-20 min | 12-20 min |
| Solar panels fuse | 2A | 3A | 4A |
| PWM dump load fuse | 10A | 10A | 16A |
| Fuse of DC output | 16A | 16A | 20A |
| Work environment temperature | -30-60°C | ||
| Relative humidity | <90% No condensation | ||
| Noise (1m) | <40dB | ||
| Degree of protection | IP20 (Indoor) IP65 (Outdoors) | ||
| Cooling method | Forced air cooling | ||
| Communication interface (optional) | RS485/USB/GPRS/WIFI/Ethernet | ||
| Temperature compensation (optional) | -4mv/°C/2V,-35°C~+80°C,Accuracy:±1°C | ||
| Size of the controller (mm) | 510*360*240 | 510*360*240 | 510*360*240 |
| Weight of the controller | 15Kg | 17Kg | 17Kg |
| Size of the dump load (mm) | 410*360*120 | 410*360*120 | 400*410*250 |
| Weight of the dump load | 7Kg | 9Kg | 13Kg |
Technical Parameters of the On Grid Wind Turbine (wind solar hybrid) Controller 5KW-10KW
| Type | FKJ-GT5KW | FKJ-GT5KW | FKJ-GT10KW | |
| Wind turbine rated power | 5KW | 5KW | 10KW | |
| Wind turbine Max. power | 10KW | 10KW | 20KW | |
| Wind turbine rated voltage | AC220V | AC380-400V | AC380-400V | |
| Solar panels power(optional) | 1.5KW | 1.5KW | 3KW | |
| Function | Rectifier,control,DC output | |||
| Automatic protection function | Over voltage protection, network electric cut off protection, regulated supply output, arrester | |||
| Manual function | Manual brake, reset, emergency switch | |||
| Display mode | LCD | |||
| Display content | Wind turbine voltage, current, power; Solar voltage, current, power; DC output voltage, DC output current, DC output power, total power. | |||
| PWM constant voltage | ≥320dc | ≥520dc | ≥520dc | |
| Wind turbine 3-phase dump load voltage | 350±5Vdc | 540±5Vdc | 540±5Vdc | |
| Wind turbine 3-phase dump load time-lapse | 12-20 min | 12-20 min | 12-20 min | |
| Solar panels fuse | 5A | 5A | 8A | |
| PWM dump load fuse | 25A | 16A | 32A | |
| Fuse of DC output | 32A | 20A | 40A | |
| Work environment temperature | -30-60°C | |||
| Relative humidity | <90% No condensation | |||
| Noise (1m) | <40dB | |||
| Degree of protection | IP20(Indoor) IP65 (Outdoors) | |||
| Cooling method | Forced air cooling | |||
| Communication interface (optional) | RS485/USB/GPRS/WIFI/Ethernet | |||
| Temperature compensation(optional) | -4mv/°C/2V,-35°C~+80°C,Accuracy:±1°C | |||
| Size of the controller (mm) | 510*360*240 | 510*360*240 | 580*400*240 | |
| Weight of the controller | 18Kg | 18Kg | 23Kg | |
| Size of the dump load (mm) | 600*450*380 | 600*450*380 | 690*450*530 | |
| Weight of the dump load | 28Kg | 28Kg | 35Kg | |
*Above parameter only for reference
1. Could be custom made to user specifications. 2, Could have solar power control subject to user demand.