Product Name: 100KW 250RPM PMG
Company Name: Jinan Deming Power Equipment Co., Ltd
Description: Introducing our hydraulic permanent magnet generator, a reliable and efficient solution for generating electric power from hydroelectric sources. With a power output of 100KW and a rotation speed of 250RPM, this generator is perfect for harnessing the power of water to generate electricity. Experience the benefits of our high-quality and durable generator set, designed to meet your power generation needs.
The wind turbine manufactured by Jinan Deming Power Equipment Co., Ltd is designed to meet the reading habits of English-speaking natives. It offers a range of features that ensure optimum performance and efficiency.
Choose the wind turbine from Jinan Deming Power Equipment Co., Ltd for reliable and efficient renewable energy generation. Experience the benefits of high performance, low noise, and long-lasting durability.
On grid wind turbine controller | WGMC50K380 | WGMC100K380 | WGMC200K380 | ||||
Wind turbine input | |||||||
Power | 50KW | 100KW | 200KW | ||||
Max. Control power / current | 100KW/200A | 200KW/400A | 400KW/800A | ||||
Rated voltage of wind turbine (AC) | 380V/400V | 380V/400V | 380V/400V | ||||
Input voltage range | AC | 0-600V | 0-600V | 0-600V | |||
DC | 0-900V | 0-900V | 0-900V | ||||
Braking voltage (DC) | Default | 550V±1% | 550V±1% | 550V±1% | |||
Set range | 530-560V | 530-560V | 530-560V | ||||
Braking current (DC) | Default | 150A | 300A | 600A | |||
Set range | 0-150A | 0-300A | 0-600A | ||||
Braking time | Default | 10-20 min | |||||
Set range | 0-5000 min | ||||||
* Generator overspeed control | Default | >300 rpm/min | |||||
Set range | 0-1000 rpm/min | ||||||
* Over wind speed control | Default | 14 m/s | |||||
Set range | 0-45 m/s | ||||||
Manual control | Manual brake , *remote control brake (with communication function) | ||||||
Automatic control function | Dump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake, * electromagnetic brake |
||||||
DC output parameters | |||||||
Output voltage range (DC) | 0-550V | 0-550V | 0-550V | ||||
Constant voltage (DC) | Default | 520V±1% | 520V±1% | 520V±1% | |||
Set range | 510-540V | 510-540V | 510-540V | ||||
Constant current (DC) | Default | 120A | 240A | 480A | |||
Set range | 0-120A | 0-240A | 0-480A | ||||
On grid wind turbine inverter | DMWG50K | DMWG100K | DMWG200K | ||||
Rated output power (AC) | 50KW | 100KW | 200KW | ||||
Max. Output power (AC) | 55KW | 110KW | 220KW | ||||
Input voltage rang (DC) | 0-800V | 0-800V | 0-800V | ||||
MPPT Voltage range (DC)(DC) | 150V-700V | 150V-700V | 150V-700V | ||||
Max. Input current (DC) | 114.6A | 229A | 458.3A | ||||
Rated current | 104A | 208A | 416.7A | ||||
THD Current harmonic | <3%(at rated power) | ||||||
Power factor | >0.99 | ||||||
Max. efficiency | 96% | ||||||
Allowable grid voltage range (AC) | 220V/380V/440V/480V (Three-phase)±20% | ||||||
Allowable grid frequency range | 50Hz/60Hz±10% | ||||||
Automatic operation conditions | DC input and power grid meet the requirements, and the inverter operates automatically | ||||||
Restart time after power failure | 2min(Adjustable) | ||||||
General parameters | |||||||
Function | Rectification, DC output, output voltage control, output current control, Dump load control, control parameter setting, wind turbine curve setting | ||||||
Automatic protection | Control part: Over voltage protection, over current protection, reverse connection protection, lightning arrester Inverter part: Polarity reverse connection protection, short circuit protection, island effect protection, LVRT,overheat protection, overload protection, ground fault protection, etc |
||||||
Display | Touch screen, LCD | ||||||
Monitoring content | Wind turbine voltage, current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speed | ||||||
Protection level | IP20(Indoor)IP65 (Outdoors) | ||||||
Telematics | RS485/USB/GPRS/WIFI/Ethernet (optional) | ||||||
Environment | Operating amb. Temp. & Hum -30-60°C,<90% no condensation | ||||||
Noise (1m) | <40dB | ||||||
Refrigeration mode | Forced air cooling | ||||||
Controller size / weight | 500*500*900mm 56kg | 600*500*1200mm 107kg | 950*550*1700mm 150kg | ||||
Dump load size / weight | 920*770*380mm 80kg | 920*770*380mm*2 150kg | 923*739*510mm*4 280kg | ||||
Inverter size / weight | 750*600*1320mm 340kg | 1460*860*1820mm 1.4t | 1460*860*1820mm 1.6t | ||||
On grid wind turbine controller | WGMC10K380 | WGMC20K380 | WGMC30K380 | |||
Wind turbine input | ||||||
Power | 10KW | 20KW | 30KW | |||
Max. Control power / current | 20KW/40A | 40KW/80A | 60KW/120A | |||
Rated voltage of wind turbine (AC) | 380V/400V | 380V/400V | 380V/400V | |||
Input voltage range | AC | 0-600V | 0-600V | 0-600V | ||
DC | 0-900V | 0-900V | 0-900V | |||
Braking voltage (DC) | Default | 550V±1% | 550V±1% | 550V±1% | ||
Set range | 530-560V | 530-560V | 530-560V | |||
Braking current (DC) | Default | 30A | 60A | 90A | ||
Set range | 0-30A | 0-60A | 0-90A | |||
Braking time | Default | 10-20 min | ||||
Set range | 0-5000 min | |||||
* Generator overspeed control | Default | >300 rpm/min | ||||
Set range | 0-1000 rpm/min | |||||
* Over wind speed control | Default | 14 m/s | ||||
Set range | 0-45 m/s | |||||
Manual control | Manual brake, *remote control brake (with communication function) | |||||
Automatic control function | Dump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake, * electromagnetic brake |
|||||
* PV. Input | ||||||
Rated power (increased) | 5KWp | 5KWp | 5KWp | |||
Working voltage (DC) | 550V / 660V | 550V / 660V | 550V / 660V | |||
DC output parameters | ||||||
Output voltage range (DC) | 0-550V | 0-550V | 0-550V | |||
Constant voltage (DC) | Default | 520V±1% | 520V±1% | 520V±1% | ||
Set range | 510-540V | 510-540V | 510-540V | |||
Constant current (DC) | Default | 24A | 48A | 72A | ||
Set range | 0-24A | 0-48A | 0-72A | |||
On grid wind turbine inverter | DMWG10KTL | DMWG20KTL | DMWG30KTL | |||
Rated output power (AC) | 10KW | 20KW | 30KW | |||
Max. Output power (AC) | 11KW | 22KW | 33KW | |||
Input voltage rang (DC) | 0-800V | 0-800V | 0-800V | |||
MPPT Voltage range (DC)(DC) | 150V-700V | 150V-700V | 150V-700V | |||
Max. Input current (DC) | 2.4A | 44.9A | 67.3A | |||
Rated current | 20.4A | 40.8A | 61.2A | |||
THD Current harmonic | <3%(at rated power) | |||||
Power factor | >0.99 | |||||
Max. efficiency | 98% | |||||
Allowable grid voltage range (AC) | 220V/380V/440V/480V (Three-phase)±20% | |||||
Allowable grid frequency range | 50Hz/60Hz±10% | |||||
Automatic operation conditions | DC input and power grid meet the requirements, and the inverter operates automatically | |||||
Restart time after power failure | 2min(Adjustable) | |||||
General parameters | ||||||
Function | Rectification, DC output, output voltage control, output current control, Dump load control, control parameter setting, wind turbine curve setting | |||||
Automatic protection | Control part: Over voltage protection, over current protection, reverse connection protection, lightning arrester Inverter part: Polarity reverse connection protection, short circuit protection, island effect protection, LVRT,overheat protection, overload protection, ground fault protection, etc |
|||||
Display | Touch screen, LCD | |||||
Monitoring content | Wind turbine voltage, current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speed | |||||
Protection level | IP20(Indoor)IP65 (Outdoors) | |||||
Telematics | RS485/USB/GPRS/WIFI/Ethernet (optional) | |||||
Environment | Operating amb. Temp. & Hum -30-60°C,<90% no condensation | |||||
Noise (1m) | <40dB | |||||
Refrigeration mode | Forced air cooling | |||||
Controller size / weight | 400*230*550mm 23kg | 500*230*620mm 35kg | 500*230*620mm 38kg | |||
Dump load size / weight | 690*450*530mm 36kg | 980*880*540mm 70kg | 980*880*540mm 70kg | |||
Inverter size / weight | 690*275*770mm 42kg | 690*275*770mm 58kg | 690*275*770mm 65kg | |||
Above parameter only for reference. Could be custom made to user specifications.
Customize your electric generator with hydroelectric power from Jinan Deming Power Equipment Co., Ltd. Choose from a range of options including permanent magnet generators, hydraulic generators, and 100kw wind generators. Our generator sets are designed to meet your specific needs. Contact us today to power up with our reliable and efficient generators.