Customization: | Available |
---|---|
Conditions of Use: |
Car Type, Trailer Type, Marine, Land Use |
Usage: | Emergency Crew, Standby Unit, Common Units |
Still deciding? Get samples of US$ 14800/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Name: Generator Set with Hydroelectric Power
Company Name: Jinan Deming Power Equipment Co., Ltd
Keywords: Hydroelectric Generator, Generator Set with Hydro Power, Pmg Generator Set, Water Mill Generator Set, 100kw Hydraulic Generator Set, Electric Power Generator, Hydro Generator Set, Permanent Magnet Power Generator, Alternator Generator Set, Motor Power Generator, Hydraulic Generator Set 20kw, 30kw Permanent Magnet Generator, 100kw Wind Generator Set, Water Power Generator, Generator Set with Hydraulic Power, Permanent Magnet Generator Set, Hydroelectric Power Generator Set, 100kw Hydro Generator, Electric Power Generator Set, Hydraulic Generator 20kw Set, Alternator Generator, Motor Generator Set, Water Generator Set, 100kw Permanent Magnet Power Generator, Hydroelectric Generator Set
Description: Introducing the 100KW 250RPM PMG Hydraulic Permanent Magnet Generator by Jinan Deming Power Equipment Co., Ltd. This generator set harnesses the power of hydroelectricity, providing a reliable and efficient source of electric power. With its permanent magnet design and 250RPM speed, this generator set is ideal for various applications, including water mills and wind power generation. Experience the benefits of a hydraulic generator set with the 100KW 250RPM PMG Hydraulic Permanent Magnet Generator.
Welcome to Jinan Deming Power Equipment Co., Ltd! We are proud to present our latest innovation in wind turbine technology.
Experience the power of our wind turbine and enjoy its numerous benefits. Choose Jinan Deming Power Equipment Co., Ltd for reliable and efficient renewable energy solutions.
On grid wind turbine controller | WGMC50K380 | WGMC100K380 | WGMC200K380 | ||||
Wind turbine input | |||||||
Power | 50KW | 100KW | 200KW | ||||
Max. Control power / current | 100KW/200A | 200KW/400A | 400KW/800A | ||||
Rated voltage of wind turbine (AC) | 380V/400V | 380V/400V | 380V/400V | ||||
Input voltage range | AC | 0-600V | 0-600V | 0-600V | |||
DC | 0-900V | 0-900V | 0-900V | ||||
Braking voltage (DC) | Default | 550V±1% | 550V±1% | 550V±1% | |||
Set range | 530-560V | 530-560V | 530-560V | ||||
Braking current (DC) | Default | 150A | 300A | 600A | |||
Set range | 0-150A | 0-300A | 0-600A | ||||
Braking time | Default | 10-20 min | |||||
Set range | 0-5000 min | ||||||
* Generator overspeed control | Default | >300 rpm/min | |||||
Set range | 0-1000 rpm/min | ||||||
* Over wind speed control | Default | 14 m/s | |||||
Set range | 0-45 m/s | ||||||
Manual control | Manual brake , *remote control brake (with communication function) | ||||||
Automatic control function | Dump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake, * electromagnetic brake |
||||||
DC output parameters | |||||||
Output voltage range (DC) | 0-550V | 0-550V | 0-550V | ||||
Constant voltage (DC) | Default | 520V±1% | 520V±1% | 520V±1% | |||
Set range | 510-540V | 510-540V | 510-540V | ||||
Constant current (DC) | Default | 120A | 240A | 480A | |||
Set range | 0-120A | 0-240A | 0-480A | ||||
On grid wind turbine inverter | DMWG50K | DMWG100K | DMWG200K | ||||
Rated output power (AC) | 50KW | 100KW | 200KW | ||||
Max. Output power (AC) | 55KW | 110KW | 220KW | ||||
Input voltage rang (DC) | 0-800V | 0-800V | 0-800V | ||||
MPPT Voltage range (DC)(DC) | 150V-700V | 150V-700V | 150V-700V | ||||
Max. Input current (DC) | 114.6A | 229A | 458.3A | ||||
Rated current | 104A | 208A | 416.7A | ||||
THD Current harmonic | <3%(at rated power) | ||||||
Power factor | >0.99 | ||||||
Max. efficiency | 96% | ||||||
Allowable grid voltage range (AC) | 220V/380V/440V/480V (Three-phase)±20% | ||||||
Allowable grid frequency range | 50Hz/60Hz±10% | ||||||
Automatic operation conditions | DC input and power grid meet the requirements, and the inverter operates automatically | ||||||
Restart time after power failure | 2min(Adjustable) | ||||||
General parameters | |||||||
Function | Rectification, DC output, output voltage control, output current control, Dump load control, control parameter setting, wind turbine curve setting | ||||||
Automatic protection | Control part: Over voltage protection, over current protection, reverse connection protection, lightning arrester Inverter part: Polarity reverse connection protection, short circuit protection, island effect protection, LVRT,overheat protection, overload protection, ground fault protection, etc |
||||||
Display | Touch screen, LCD | ||||||
Monitoring content | Wind turbine voltage, current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speed | ||||||
Protection level | IP20(Indoor)IP65 (Outdoors) | ||||||
Telematics | RS485/USB/GPRS/WIFI/Ethernet (optional) | ||||||
Environment | Operating amb. Temp. & Hum -30-60°C,<90% no condensation | ||||||
Noise (1m) | <40dB | ||||||
Refrigeration mode | Forced air cooling | ||||||
Controller size / weight | 500*500*900mm 56kg | 600*500*1200mm 107kg | 950*550*1700mm 150kg | ||||
Dump load size / weight | 920*770*380mm 80kg | 920*770*380mm*2 150kg | 923*739*510mm*4 280kg | ||||
Inverter size / weight | 750*600*1320mm 340kg | 1460*860*1820mm 1.4t | 1460*860*1820mm 1.6t | ||||
On grid wind turbine controller | WGMC10K380 | WGMC20K380 | WGMC30K380 | |||
Wind turbine input | ||||||
Power | 10KW | 20KW | 30KW | |||
Max. Control power / current | 20KW/40A | 40KW/80A | 60KW/120A | |||
Rated voltage of wind turbine (AC) | 380V/400V | 380V/400V | 380V/400V | |||
Input voltage range | AC | 0-600V | 0-600V | 0-600V | ||
DC | 0-900V | 0-900V | 0-900V | |||
Braking voltage (DC) | Default | 550V±1% | 550V±1% | 550V±1% | ||
Set range | 530-560V | 530-560V | 530-560V | |||
Braking current (DC) | Default | 30A | 60A | 90A | ||
Set range | 0-30A | 0-60A | 0-90A | |||
Braking time | Default | 10-20 min | ||||
Set range | 0-5000 min | |||||
* Generator overspeed control | Default | >300 rpm/min | ||||
Set range | 0-1000 rpm/min | |||||
* Over wind speed control | Default | 14 m/s | ||||
Set range | 0-45 m/s | |||||
Manual control | Manual brake, *remote control brake (with communication function) | |||||
Automatic control function | Dump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake, * electromagnetic brake |
|||||
* PV. Input | ||||||
Rated power (increased) | 5KWp | 5KWp | 5KWp | |||
Working voltage (DC) | 550V / 660V | 550V / 660V | 550V / 660V | |||
DC output parameters | ||||||
Output voltage range (DC) | 0-550V | 0-550V | 0-550V | |||
Constant voltage (DC) | Default | 520V±1% | 520V±1% | 520V±1% | ||
Set range | 510-540V | 510-540V | 510-540V | |||
Constant current (DC) | Default | 24A | 48A | 72A | ||
Set range | 0-24A | 0-48A | 0-72A | |||
On grid wind turbine inverter | DMWG10KTL | DMWG20KTL | DMWG30KTL | |||
Rated output power (AC) | 10KW | 20KW | 30KW | |||
Max. Output power (AC) | 11KW | 22KW | 33KW | |||
Input voltage rang (DC) | 0-800V | 0-800V | 0-800V | |||
MPPT Voltage range (DC)(DC) | 150V-700V | 150V-700V | 150V-700V | |||
Max. Input current (DC) | 2.4A | 44.9A | 67.3A | |||
Rated current | 20.4A | 40.8A | 61.2A | |||
THD Current harmonic | <3%(at rated power) | |||||
Power factor | >0.99 | |||||
Max. efficiency | 98% | |||||
Allowable grid voltage range (AC) | 220V/380V/440V/480V (Three-phase)±20% | |||||
Allowable grid frequency range | 50Hz/60Hz±10% | |||||
Automatic operation conditions | DC input and power grid meet the requirements, and the inverter operates automatically | |||||
Restart time after power failure | 2min(Adjustable) | |||||
General parameters | ||||||
Function | Rectification, DC output, output voltage control, output current control, Dump load control, control parameter setting, wind turbine curve setting | |||||
Automatic protection | Control part: Over voltage protection, over current protection, reverse connection protection, lightning arrester Inverter part: Polarity reverse connection protection, short circuit protection, island effect protection, LVRT,overheat protection, overload protection, ground fault protection, etc |
|||||
Display | Touch screen, LCD | |||||
Monitoring content | Wind turbine voltage, current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speed | |||||
Protection level | IP20(Indoor)IP65 (Outdoors) | |||||
Telematics | RS485/USB/GPRS/WIFI/Ethernet (optional) | |||||
Environment | Operating amb. Temp. & Hum -30-60°C,<90% no condensation | |||||
Noise (1m) | <40dB | |||||
Refrigeration mode | Forced air cooling | |||||
Controller size / weight | 400*230*550mm 23kg | 500*230*620mm 35kg | 500*230*620mm 38kg | |||
Dump load size / weight | 690*450*530mm 36kg | 980*880*540mm 70kg | 980*880*540mm 70kg | |||
Inverter size / weight | 690*275*770mm 42kg | 690*275*770mm 58kg | 690*275*770mm 65kg | |||
Customize your generator set with hydroelectric power from Jinan Deming Power Equipment Co., Ltd. Choose from a range of options including hydro power, PMG generator set, water mill generator set, and more. Get the perfect solution for your power needs.