Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 8549/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Type | NB480-50KSZ | NB380-50KSZ | |
DC input | Input rated voltage | 480 VDC | 380 VDC |
Input rated current | 115 A | 146 A | |
Input DC voltage range | 400-620 VDC | 320-496VDC | |
AC input (AC Bypass) |
Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
Input rated current | 139A / 76A / 72.5A | ||
Bypass transfer time | ≤100ms (Can be customized ≤4ms version) | ||
AC output | Output rated power | 50KW | |
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz | ||
Output rated current | 139A / 76A / 72.5A | ||
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | ||
Output frequency accuracy | 50Hz / 60Hz ±0.05% | ||
Waveform distortion (THD). | ≤3% (Linear load) | ||
Dynamic response time (Load 0←→100%) |
2ms | ||
Power factor (PF) | 1 | ||
Overload capacity | 120%,5 minutes;200%,3 seconds | ||
Crest factor (CF) | 3:1 | ||
Inverter efficiency | 94% | ||
Working Environment | Dielectric strength | 1500VAC,1minute | |
Noise (1m) | ≤50dB | ||
Ambient temperature | -20ºC~+60ºC | ||
Humidity | 0~90%, No condensation | ||
Altitude | <6000m Higher than 2000m rated power should be reduced | ||
Pure Sine Wave | Yes | ||
Equipped with copper transformer | Yes | ||
Communication mode | RS485,Wifi,GPRS,Ethernet (Modbus RTU protocol) | ||
AC Charger | Optional | ||
Solar Charger | Optional | ||
Generator port | Optional | ||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
Size(mm) | 660*1300*1600mm | ||
Weight(kg) | 450kg |
Type | NB380-60KSZ | NB480-60KSZ | |
DC input | 220 VDC | 380 VDC | 480 VDC |
68 A | 175 A | 139 A | |
180-300 VDC | 320-496VDC | 400-620 VDC | |
AC input (AC Bypass) |
Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
Input rated current | 153.6A / 91A / 86A | ||
Bypass transfer time | ≤100ms (Can be customized ≤4ms version) | ||
AC output | Output rated power | 60KW | |
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz | ||
Output rated current | 153.6A / 91A / 86A | ||
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | ||
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||
Waveform distortion (THD). | ≤3% (Linear load) | ||
Dynamic response time (Load 0←→100%) |
2ms | ||
Power factor (PF) | 1 | ||
Overload capacity | 120%,5 minutes;200%,3 seconds | ||
Crest factor (CF) | 3:1 | ||
Inverter efficiency | 94% | ||
Working Environment | Dielectric strength | 1500VAC,1minute | |
Noise (1m) | ≤50dB | ||
Ambient temperature | -20ºC~+60ºC | ||
Humidity | 0~90%, No condensation | ||
Altitude | <6000m Higher than 2000m rated power should be reduced | ||
Pure Sine Wave | Yes | ||
Equipped with copper transformer | Yes | ||
Communication mode | RS485,Wifi,GPRS,Ethernet (Modbus RTU protocol) | ||
AC Charger | Optional | ||
Solar Charger | Optional | ||
Generator port | Optional | ||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
Size(mm) | 750*1500*1700mm | ||
Weight(kg) | 680kg |
Type | NB380-75KSZ | NB240-75KSZ | |
DC input | Input rated voltage | 380 VDC | 240 VDC |
Input rated current | 219 A | 347 A | |
Input DC voltage allowing range | 320-496 VDC | 200-310 VDC | |
AC input (AC Bypass) |
Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
Input rated current | 192A /114A / 108A | ||
Bypass transfer time | ≤100ms (Can be customized ≤4ms version) | ||
AC output | Output rated power | 75KW | |
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz | ||
Output rated current | 192A /114A / 108A | ||
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | ||
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||
Waveform distortion (THD). | ≤3% (Linear load) | ||
Dynamic response time (Load 0←→100%) |
2ms | ||
Power factor (PF) | 1 | ||
Overload capacity | 120%,5 minutes;200%,3 seconds | ||
Crest factor (CF) | 3:1 | ||
Inverter efficiency | 94% | ||
Working Environment | Dielectric strength | 1500VAC,1minute | |
Noise (1m) | ≤50dB | ||
Ambient temperature | -20ºC~+60ºC | ||
Humidity | 0~90%, No condensation | ||
Altitude | <6000m Higher than 2000m rated power should be reduced | ||
Pure Sine Wave | Yes | ||
Equipped with copper transformer | Yes | ||
Communication mode | RS485,Wifi,GPRS,Ethernet (Modbus RTU protocol) | ||
AC Charger | Optional | ||
Solar Charger | Optional | ||
Generator port | Optional | ||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
Size(mm) | 750*1500*1700mm | ||
Weight(kg) | 680kg |
Type | NB360-100KSZ | NB380-100KSZ | |
DC input | Input rated voltage | 360 VDC | 380 VDC |
Input rated current | 309 A | 292 A | |
Input DC voltage range | 300-465 VDC | 320-496VDC | |
AC input (AC Bypass) |
Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
Input rated current | 278A / 152A / 145A | ||
Bypass transfer time | ≤100 ms (Can be customized ≤ 4ms version) | ||
AC output | Output rated power | 100KW | |
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC ,50Hz / 60Hz | ||
Output rated current | 278A / 152A / 145A | ||
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | ||
Output frequency accuracy | 50Hz / 60Hz ±0.05% | ||
Waveform distortion (THD). | ≤3% (Linear load) | ||
Dynamic response time (Load 0←→100%) |
2ms | ||
Power factor (PF) | 1 | ||
Overload capacity | 120%,5 minutes;200%,3 seconds | ||
Crest factor (CF) | 3:1 | ||
Inverter efficiency | 94% | ||
Working Environment | Dielectric strength | 1500VAC,1minute | |
Noise (1m) | ≤50dB | ||
Ambient temperature | -20ºC~+60ºC | ||
Humidity | 0~90%,No condensation | ||
Altitude | <6000m Higher than 2000m rated power should be reduced | ||
Pure Sine Wave | Yes | ||
Equipped with copper transformer | Yes | ||
Communication mode | RS485,Wifi,GPRS,Ethernet (Modbus RTU protocol) | ||
AC Charger | Optional | ||
Solar Charger | Optional | ||
Generator port | Optional | ||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
Size(mm) | Product Size: 650*1400*1500 | Package Size: 750*1500*1700 | |
Weight(kg) | 730kg |