Customization: | Available |
---|---|
After-sales Service: | Provide |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Type | 1KW12V | 1KW-24Vdc | 1KW-48Vdc |
Wind turbine rated power | 1KW | 1KW | 1KW |
Wind turbine max. power | 2KW | 2KW | 2KW |
*Solar panel power | 300Wp | 300Wp | 300Wp |
Battery | 12Vdc | 24Vdc | 48Vdc |
Function | Rectifier,charge, control, *DC output | ||
Automatic protection function | Over voltage protection, constant voltage charge, arrester | ||
Manual function | Manual brake | ||
Display mode | LCD+LED | ||
Display content | Wind turbine voltage, current, power; solar panel voltage, current, power; battery voltage, charge current | ||
PWM constant pressure voltage | >14Vdc | >29Vdc | >58Vdc |
Wind turbine 3-phase dump load voltage | 15±1Vdc | 30±1Vdc | 60±1Vdc |
Wind turbine recharge voltage | 13.5±1Vdc | 27±1Vdc | 54±1Vdc |
* Solar control stop charging voltage | 15±1Vdc | 29±1Vdc | 58±1Vdc |
*Solar control recharge voltage | <14Vdc | <29Vdc | <58Vdc |
*Diesel generator starting voltage | 10±1Vdc | 20±1Vdc | 40±1Vdc |
*Diesel generator off voltage | 13.5±1Vdc | 27±1Vdc | 54±1Vdc |
Self-provided battery connecting wire | >16 mm² | >8mm² | >6mm² |
PWM fuse | 100A | 50A | 25A |
* Solar fuse | 32A | 16A | 10A |
Charging fuse | 125A | 63A | 40A |
Work environment temperature | -30-60°C | ||
Relative humidity | <90% No condensation | ||
Noise (1m) | <40dB | ||
Degree of protection | IP20(Indoor)IP65 (Outdoors) | ||
Cooling method | Forced air cooling | ||
* Extral Control function (optional) | Yawing, variable pitch, mechanical brake, hydraulic brake, electromagnetism brake | ||
* Communication interface (optional) | RS485/USB/GPRS/WIFI/Ethernet | ||
*Temperature compensation (optional) | -4mv/°C/2V,-35°C~+80°C,Accuracy:±1°C | ||
Controller Size (mm) Weight (kg) | 510*360*240 17 Kg | 510*360*240 17 Kg | 510*360*240 17 Kg |
Dump load Size (mm) Weight (kg) | 290*250*120 5 Kg | 290*250*120 5 Kg | 290*250*120 5 Kg |
Type | 2KW-24Vdc | 2KW-48Vdc | 2KW-96Vdc |
Wind turbine rated power | 2KW | 2KW | 2KW |
Wind turbine max. power | 4KW | 4KW | 4KW |
*Solar panel power | 600Wp | 600Wp | 600Wp |
Battery | 24Vdc | 48Vdc | 96Vdc |
Function | Rectifier,charge, control, *DC output | ||
Automatic protection function | Over voltage protection, constant voltage charge, arrester | ||
Manual function | Manual brake | ||
Display mode | LCD+LED | ||
Display content | Wind turbine voltage, current, power; solar panel voltage, current, power; battery voltage, charge current | ||
PWM constant pressure voltage | >29Vdc | >58Vdc | >116Vdc |
Wind turbine 3-phase dump load voltage | 30±1Vdc | 60±1Vdc | 120±2Vdc |
Wind turbine recharge voltage | 27±1Vdc | 54±1Vdc | 108±2Vdc |
*Solar control stop charging voltage | 29±1Vdc | 58±1Vdc | 116±2Vdc |
*Solar control recharge voltage | <29Vdc | <58Vdc | <116Vdc |
*Diesel generator starting voltage | 20±1Vdc | 40±1Vdc | 80±2Vdc |
*Diesel generator off voltage | 27±1Vdc | 54±1Vdc | 108±2Vdc |
Self-provided battery connecting wire | >20mm² | >10mm² | >24mm² |
PWM fuse | 100A | 50A | 32A |
*Solar fuse | 32A | 16A | 10A |
Charging fuse | 125A | 63A | 40A |
Work environment temperature | -30-60°C | ||
Relative humidity | <90% No condensation | ||
Noise (1m) | <40dB | ||
Degree of protection | IP20(Indoor)IP65 ( Outdoors ) | ||
Cooling method | Forced air cooling | ||
*Extral Control function (optional) | Yawing, variable pitch, mechanical brake, hydraulic brake, electromagnetism brake | ||
* Communication interface (optional) | RS485/USB/GPRS/WIFI/Ethernet | ||
*Temperature compensation (optional) | -4mv/°C/2V,-35°C~+80°C, Accuracy:±1°C | ||
Controller Size (mm) Weight (kg) | 580*400*240 22 Kg | 510*360*240 17 Kg | 510*360*240 17 Kg |
Dump load Size (mm) Weight (kg) | 410*290*120 8 Kg | 410*290*120 8 Kg | 410*290*120 8 Kg |
Type | 3KW-24Vdc | 3KW-48Vdc | 3KW-96Vdc |
Wind turbine rated power | 3KW | 3KW | 3KW |
Wind turbine max. power | 6KW | 6KW | 6KW |
*Solar panel power | 900Wp | 900Wp | 900Wp |
Battery | 24Vdc | 48Vdc | 96Vdc |
Function | Rectifier,charge, control, *DC output | ||
Automatic protection function | Over voltage protection, constant voltage charge, arrester | ||
Manual function | Manual brake | ||
Display mode | LCD+LED | ||
Display content | Wind turbine voltage, current, power; solar panel voltage, current, power; battery voltage, charge current | ||
PWM constant pressure voltage | >29Vdc | >58Vdc | >116Vdc |
Wind turbine 3-phase dump load voltage | 30±1Vdc | 60±1Vdc | 120±2Vdc |
Wind turbine recharge voltage | 27±1Vdc | 54±1Vdc | 108±2Vdc |
*Solar control stop charging voltage | 30±1Vdc | 60±1Vdc | 120±2Vdc |
*Solar control recharge voltage | <29Vdc | <58Vdc | <116Vdc |
*Diesel generator starting voltage | 20±1Vdc | 40±1Vdc | 80±2Vdc |
*Diesel generator off voltage | 27±1Vdc | 54±1Vdc | 108±2Vdc |
Self-provided battery connecting wire | >30mm² | >12mm² | >6mm² |
PWM fuse | 160A | 80A | 40A |
*Solar fuse | 50A | 25A | 12A |
Charging fuse | 190A | 125A | 63A |
Work environment temperature | -30-60°C | ||
Relative humidity | <90% No condensation | ||
Noise (1m) | <40dB | ||
Degree of protection | IP20(Indoor)IP65 (Outdoors) | ||
Cooling method | Forced air cooling | ||
*Extral Control function (optional) | Yawing, variable pitch, mechanical brake, hydraulic brake, electromagnetism brake | ||
*Communication interface (optional) | RS485/USB/GPRS/WIFI/Ethernet | ||
*Temperature compensation (optional) | -4mv/°C/2V,-35°C~+80°C,Accuracy:±1°C | ||
Controller Size (mm) Weight (kg) | 580*400*240 23Kg | 510*360*240 18Kg | 510*360*240 17Kg |
Dump load Size (mm) Weight (kg) | 400*410*250 13Kg | 400*410*250 13Kg | 400*410*250 13Kg |
Type | 5KW-48Vdc | 5KW-120Vdc | 5KW-240Vdc |
Wind turbine rated power | 5KW | 5KW | 5KW |
Wind turbine max. power | 10KW | 10KW | 10KW |
* Solar panel power | 1.5KWp | 1.5KWp | 1.5KWp |
Battery | 48Vdc | 120Vdc | 240Vdc |
Function | Rectifier,charge, control, *DC output | ||
Automatic protection function | Over voltage protection, constant voltage charge, arrester | ||
Manual function | Manual brake | ||
Display mode | LCD+LED | ||
Display content | Wind turbine voltage, current, power; solar panel voltage, current, power; battery voltage, charge current | ||
PWM constant pressure voltage | >58Vdc | >145Vdc | >290 Vdc |
Wind turbine 3-phase dump load voltage | 60±1Vdc | 150±2Vdc | 300±5Vdc |
Wind turbine recharge voltage | 54±1Vdc | 135±2Vdc | 280±5Vdc |
*Solar control stop charging voltage | 60±1Vdc | 150±2Vdc | 300±5Vdc |
*Solar control recharge voltage | 54±1Vdc | 135±2Vdc | 280±5Vdc |
*Diesel generator starting voltage | 40±1Vdc | 100±2Vdc | 200±5Vdc |
*Diesel generator off voltage | 54±1Vdc | 135±2Vdc | 270±5Vdc |
Self-provided battery connecting wire | >20mm² | >10mm² | >6mm² |
PWM fuse | 125A | 50A | 32A |
*Solar fuse | 40A | 16A | 10A |
Charging fuse | 160A | 63A | 40A |
Work environment temperature | -30-60°C | ||
Relative humidity | <90% No condensation | ||
Noise (1m) | <40dB | ||
Degree of protection | IP20(Indoor)IP65 (Outdoors) | ||
Cooling method | Forced air cooling | ||
*Extral Control function (optional) | Yawing, variable pitch, mechanical brake, hydraulic brake, electromagnetism brake | ||
*Communication interface (optional) | RS485/USB/GPRS/WIFI/Ethernet | ||
*Temperature compensation (optional) | -4mv/°C/2V,-35°C~+80°C,Accuracy:±1°C | ||
Controller Size (mm) Weight (kg) | 580*400*240 23Kg | 510*360*240 17Kg | 510*360*240 17Kg |
Dump load Size (mm) Weight (kg) | 600*450*380 28Kg | 600*450*380 28Kg | 600*450*380 28Kg |
Product Name: Off Grid Wind Solar Hybrid Charge Controller with Dump Load
Company Name: Jinan Deming Power Equipment Co., Ltd
Description: This customizable Off Grid Wind Solar Hybrid Charge Controller with Dump Load is designed to meet the specific requirements of users. It combines the power of wind and solar energy, providing efficient and reliable charging for off-grid systems. Choose from a range of parameters to suit your needs. Ideal for hybrid wind and solar power systems.