Customization: | Available |
---|---|
Output Power: | >1000W |
Product Name: | 50kw on Grid Wind Turbine Controller |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
On grid wind turbine controller | WGMC50K380 | WGMC100K380 | WGMC200K380 | |||||
Wind turbine input | ||||||||
Power | 50KW | 100KW | 200KW | |||||
Max. Control power / current | 100KW/200A | 200KW/400A | 400KW/800A | |||||
Rated voltage of wind turbine (AC) | 380V/400V | 380V/400V | 380V/400V | |||||
Input voltage range | AC | 0-600V | 0-600V | 0-600V | ||||
DC | 0-900V | 0-900V | 0-900V | |||||
Braking voltage (DC) | Default | 550V±1% | 550V±1% | 550V±1% | ||||
Set range | 530-560V | 530-560V | 530-560V | |||||
Braking current (DC) | Default | 150A | 300A | 600A | ||||
Set range | 0-150A | 0-300A | 0-600A | |||||
Braking time | Default | 10-20 min | ||||||
Set range | 0-5000 min | |||||||
*Generator overspeed control | Default | >300 rpm/min | ||||||
Set range | 0-1000 rpm/min | |||||||
*Over wind speed control | Default | 14 m/s | ||||||
Set range | 0-45 m/s | |||||||
Manual control | Manual brake , *remote control brake (with communication function) | |||||||
Automatic control function | Dump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake, * electromagnetic brake |
|||||||
DC output parameters | ||||||||
Output voltage range (DC) | 0-550V | 0-550V | 0-550V | |||||
Constant voltage (DC) | Default | 520V±1% | 520V±1% | 520V±1% | ||||
Set range | 510-540V | 510-540V | 510-540V | |||||
Constant current (DC) | Default | 120A | 240A | 480A | ||||
Set range | 0-120A | 0-240A | 0-480A | |||||
On grid wind turbine inverter | DMWG50K | DMWG100K | DMWG200K | |||||
Rated output power (AC) | 50KW | 100KW | 200KW | |||||
Max. Output power (AC) | 55KW | 110KW | 220KW | |||||
Input voltage rang (DC) | 0-800V | 0-800V | 0-800V | |||||
MPPT Voltage range (DC) | 350V-750V | 350V-750V | 350V-750V | |||||
Max. Input current (DC) | 114.6A | 229A | 458.3A | |||||
Rated current | 104A | 208A | 416.7A | |||||
THD Current harmonic | <3%(At rated power) | |||||||
Power factor | 0.8 leading-1-0.8lagging, adjustable | |||||||
Max. efficiency | 96% | |||||||
Electrical structure | Power frequency transformer | |||||||
Allowable grid voltage range (AC) | 220V/380V/440V/480V (Three-phase)±20% | |||||||
Allowable grid frequency range | 50Hz/60Hz±10% | |||||||
Automatic operation conditions | DC input and power grid meet the requirements, and the inverter operates automatically | |||||||
Restart time after power failure | 30s (Adjustable) | |||||||
General parameters | ||||||||
Function | Rectification, DC output, output voltage control, output current control, Dump load control, control parameter setting, wind turbine curve setting | |||||||
Automatic protection | Control part: Over voltage protection, over current protection, reverse connection protection, lightning arrester Inverter part: Polarity reverse connection protection, short circuit protection, island effect protection, LVRT, overheat protection, overload protection, ground fault protection, etc |
|||||||
Display | Touch screen, LCD | |||||||
Monitoring content | Wind turbine voltage, current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speed | |||||||
Protection level | IP20(Indoor)IP65 (Outdoors) | |||||||
Telematics | RS485/USB/GPRS/WIFI/Ethernet (Optional) | |||||||
Environment | Operating amb. Temp. & Hum -30-60°C,<90% no condensation | |||||||
Noise (1m) | <40dB | |||||||
Refrigeration mode | Forced air cooling | |||||||
Size / Weight | ||||||||
Controller size / weight | 500*500*900mm 56kg | 600*500*1200mm 107kg | 950*550*1700mm 150kg | |||||
Dump load size / weight | 920*770*380mm 80kg | 920*770*380mm×2 150kg | 923*739*510mm×4 280kg | |||||
Inverter size / weight | 750*600*1320mm 340kg | 1460*860*1820mm 600kg | 1460*860*1820mm 900kg |