| Type | NB48-3KSZ | NB96-3KSZ | NB120-3KSZ | NB240-3KSZ | ||
| DC input | Input rated voltage | 48 VDC | 96 VDC | 120 VDC | 240 VDC | |
| Input rated current | 69 A | 35 A | 28 A | 14 A | ||
| Input DC voltage range | 40-62VDC | 80-124 VDC | 100-155 VDC | 200-310 VDC | ||
| AC input (AC Bypass) |
Allow input voltage range | 220 VAC / 380 VAC / 400 VAC± 15% VAC | ||||
| Input rated current | 8A / 4.5 A / 4.3 A | |||||
| Bypass transfer time | ≤40 ms (Can be customized ≤ 4ms version) | |||||
| AC output | Output rated power | 3KW | ||||
| Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz | |||||
| Output rated current | 8A / 4.5 A / 4.3 A | |||||
| Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | |||||
| Output frequency accuracy | 50Hz / 60Hz ± 0.05% | |||||
| Waveform distortion (THD). | ≤3% (Linear load) | |||||
| Dynamic response time (Load 0←→100%) |
2ms | |||||
| Power factor (PF) | 1 | |||||
| Overload capacity | 120%,5 minutes;200%,3 seconds | |||||
| Crest factor (CF) | 3:1 | |||||
| Inverter efficiency | 94% | |||||
| Working Environment | Dielectric strength | 1500VAC,1minute | ||||
| Noise (1m) | ≤50dB | |||||
| Ambient temperature | -20ºC~+60ºC | |||||
| Humidity | 0~90%, No condensation | |||||
| Altitude | <6000m Higher than 2000m rated power should be reduced | |||||
| Pure Sine Wave | Yes | |||||
| Equipped with isolated copper transformer | Yes | |||||
| Communication mode | RS485,Wifi,GPRS,Ethernet (Modbus RTU protocol) | |||||
| Solar Charger | Optional, available | |||||
| AC Charger | Optional, available | |||||
| Generator Port | Optional, available | |||||
| Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |||||
| Product Size | 400*660*800mm | |||||
| Weight | 100kg | |||||
| Type | NB48-5KSZ | NB96-5KSZ | NB120-5KSZ | NB240-5KSZ | |
| DC input | Input rated voltage | 48 VDC | 96 VDC | 120 VDC | 240 VDC |
| Input rated current | 116 A | 58 A | 46 A | 23 A | |
| Input DC voltage range | 40-62VDC | 80-124 VDC | 100-155 VDC | 200-310 VDC | |
AC input (AC Bypass) |
Allow input voltage range | 220 VAC / 380 VAC / 400 VAC± 15% VAC | |||
| Input rated current | 14A / 8 A / 7.5A | ||||
| Bypass transfer time | ≤ 40ms (Can be customized ≤ 4ms version) | ||||
| AC output | Output rated power | 5KW | |||
| Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz | ||||
| Output rated current | 14A / 8 A / 7.5A | ||||
| Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | ||||
| Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||||
| Waveform distortion (THD). | ≤3% (Linear load) | ||||
| Dynamic response time (Load 0←→100%) |
2ms | ||||
| Power factor (PF) | 1 | ||||
| Overload capacity | 120%,5 minutes;200%,3 seconds | ||||
| Crest factor (CF) | 3:1 | ||||
| Inverter efficiency | 94% | ||||
| Working Environment | Dielectric strength | 1500VAC,1minute | |||
| Noise (1m) | 0≤50dB | ||||
| Ambient temperature | -20ºC~+60ºC | ||||
| Humidity | 0~90%, No condensation | ||||
| Altitude | <6000m Higher than 2000m rated power should be reduced | ||||
| Pure Sine Wave | Yes | ||||
| Equipped with isolated copper transformer | Yes | ||||
| Communication mode | RS485,Wifi,GPRS,Ethernet (Modbus RTU protocol) | ||||
| Solar Charger | Optional, available | ||||
| AC Charger | Optional, available | ||||
| Generator Port | Optional, available | ||||
| Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||||
| Product Size | 400*660*800mm | ||||
| Weight | 120kg | ||||
| Type | NB48-7.5KSZ | NB96-7.5KSZ | NB120-7.5KSZ | NB240-7.5KSZ | ||
| DC input | Input rated voltage | 48 VDC | 96 VDC | 120 VDC | 240 VDC | |
| Input rated current | 174 A | 87 A | 69 A | 35 A | ||
| Input DC voltage range | 40-62VDC | 80-124 VDC | 100-155 VDC | 200-310 VDC | ||
| AC input (AC Bypass) |
Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | ||||
| Input rated current | 21A / 11.5A / 10.5A | |||||
| Bypass transfer time | ≤40ms (Can be customized ≤4ms version) | |||||
| AC output | Output rated power | 7.5KW | ||||
| Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz | |||||
| Output rated current | 21A / 11.5A / 10.5A | |||||
| Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | |||||
| Output frequency accuracy | 50Hz / 60Hz ± 0.05% | |||||
| Waveform distortion (THD). | ≤3% (Linear load) | |||||
| Dynamic response time (Load 0←→100%) |
2ms | |||||
| Power factor (PF) | 1 | |||||
| Overload capacity | 120%,5 minutes;200%,3 seconds | |||||
| Crest factor (CF) | 3:1 | |||||
| Inverter efficiency | 94% | |||||
| Working Environment | Dielectric strength | 1500VAC,1minute | ||||
| Noise (1m) | ≤50dB | |||||
| Ambient temperature | -20ºC~+60ºC | |||||
| Humidity | 0~90%, No condensation | |||||
| Altitude | <6000m Higher than 2000m rated power should be reduced | |||||
| Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |||||
| Pure Sine Wave | Yes | |||||
| Equipped with copper transformer | Yes | |||||
| Communication mode | RS485,Wifi,GPRS,Ethernet (Modbus RTU protocol) | |||||
| Solar Charger | Optional, available | |||||
| AC Charger | Optional, available | |||||
| Generator Port | Optional, available | |||||
| Size(mm) | 550*480*1200mm | |||||
| Weight(kg) | 150kg | |||||