Customization: | Available |
---|---|
Nature of Source Flow: | Passive inverter |
Certification: | ISO9001, RoHS, CE |
Still deciding? Get samples of US$ 4200/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Power Frequency Pure Sine Wave Inverter Features:
1.Complete isolation-type inverter technology, noiseless output.30KVA off grid single phase inverter technical parameters
Model | NB110-30KDZ | NB220-30KDZ | NB380-30KDZ | |
DC input |
Input rated voltage | 110 VDC | 220 VDC | 380 VDC |
Input rated current | 303A | 151.5 A | 87.7A | |
Input DC voltage allowing range | 90- 140VDC | 180-280 VDC | 320-500VDC | |
AC input (AC bypass) |
Allow input voltage range | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% | ||
Input rated current | 272A / 250A / 136 A /125A | |||
Bypass transfer time | ≤40 ms (4ms optional) | |||
AC output | Rated capacity | 30KVA | ||
Output rated voltage and frequency | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | |||
Output rated current | 272A / 250A / 136 A /125A | |||
Output voltage accuracy | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 2% | |||
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | |||
Wave | Pure sine wave (Isolation transformer) | |||
THD. | ≤3%(Linear load) | |||
Power factor (PF) | 0.8 | |||
Overload capacity | 120%,10 minutes | |||
Overcurrent capacity | 200%,10 seconds | |||
Crest factor (CF) | 3:1 | |||
Inverter efficiency | >92% | |||
Working Environment | Dielectric strength | 1500VAC,1minute | ||
Noise (1m) | ≤50dB | |||
Ambient temperature | -10ºC~+50ºC | |||
Humidity | 0~90%, No condensation | |||
Altitude | <2000m Higher than 2000m rated power should be reduced |
|||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |||
Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | |||
Equipped With Copper Transformer | Yes | |||
Solar Charger | Optional | |||
AC Charger | Optional | |||
Generator Port | Optional | |||
Size | 630*1000*1430 mm | |||
Weight | 295 Kg |
20KW off grid three phase inverter technical parameters
Type | NB216-20KSZ | |
DC input | Input rated voltage | 216VDC |
Input rated current | 102.9A | |
Input DC voltage allowing range | 180-280VDC | |
AC bypass | Allow input voltage range | 380VAC± 15% VAC |
Input rated current | 30.4A | |
Bypass transfer time | ≤100ms(4ms optional) | |
AC output | Rated capacity | 20KW |
Output rated voltage and frequency | Three phase 380VAC,50Hz/60HZ | |
Output rated current | 30.4A | |
Output voltage accuracy | 380VAC ± 2% | |
Output frequency accuracy | 50Hz ± 0.05% | |
Wave | Pure sine wave (Isolation transformer) | |
THD. | ≤3%(Linear load) | |
Power factor (PF) | 1 | |
Overload capacity | 120%,10 minutes | |
Overcurrent capacity | 200%,10 seconds | |
Crest factor (CF) | 3:1 | |
Inverter efficiency | >92% | |
Working Environment | Dielectric strength | 1500VAC,1minute |
Noise (1m) | ≤50dB | |
Ambient temperature | -10ºC~+50ºC | |
Humidity | 0~90%, No condensation | |
Altitude | <2000m Higher than 2000m rated power should be reduced |
|
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |
Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | |
Ac charger | (optional) | |
Battery, City grid (generator) priority | (optional) | |
Size | 550×1050×1340mm | |
Weight | 220KG |
50KW off grid three phase inverter technical parameters
Type | NB384-50KSZ | |
DC input | Input rated voltage | 384VDC |
Input rated current | 144.7A | |
Input DC voltage allowing range | 320-480VDC | |
AC bypass | Allow input voltage range | 380VAC± 15% VAC |
Input rated current | 76A | |
Bypass transfer time | ≤100ms(4ms optional) | |
AC output | Output rated power | 50KW |
Output rated voltage and frequency | Three phase 380VAC,50HZ (Three phase four wire) |
|
Output rated current | 76A | |
Output voltage accuracy | 380VAC ± 2% | |
Output frequency accuracy | 50Hz ± 0.05% | |
Wave | Pure sine wave (Isolation transformer) | |
THD. | ≤3%(Linear load) | |
Power factor (PF) | 1 | |
Overload capacity | 120%,10 minutes | |
Overcurrent capacity | 200%,10 seconds | |
Crest factor (CF) | 3:1 | |
Inverter efficiency | >92% | |
Working Environment | Dielectric strength | 1500VAC,1minute |
Noise (1m) | ≤50dB | |
Ambient temperature | -10ºC~+50ºC | |
Humidity | 0~90%, No condensation | |
Altitude | <2000m Higher than 2000m rated power should be reduced |
|
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |
Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | |
Ac charger | (optional) | |
Battery, City grid (generator) priority | (optional) | |
Size | 630*1310*1573mm | |
Weight | 430KG |