Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
On grid wind turbine controller | WGMC10K380 | WGMC20K380 | WGMC30K380 | ||
Wind turbine input | |||||
Power | 10KW | 20KW | 30KW | ||
Max. Control power | 20KW | 40KW | 60KW | ||
Rated voltage of wind turbine (AC) | 380V/400V | 380V/400V | 380V/400V | ||
Input voltage range | AC 0-600V | AC 0-600V | AC 0-600V | ||
DC 0-900V | DC 0-900V | DC 0-900V | |||
Braking voltage (DC) | 550V±1% | 550V±1% | 550V±1% | ||
Braking current (DC) | 30A | 60A | 90A | ||
Braking time min | 10-20 min | ||||
Manual control | Manual brake | ||||
Automatic control function | Dump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake, * electromagnetic brake | ||||
* PV. Input | |||||
Rated power (increased) | 5KWp | 5KWp | 5KWp | ||
Working voltage (DC) | 550V / 660V | 550V / 660V | 550V / 660V | ||
DC output parameters | |||||
Output voltage range (DC) | 0-550V | 0-550V | 0-550V | ||
Constant voltage (DC) | 520V±1% | 520V±1% | 520V±1% | ||
On grid wind turbine inverter | DMWG10KTL | DMWG20KTL | DMWG30KTL | ||
Rated output power (AC) | 10KW | 20KW | 30KW | ||
Max. Output power (AC) | 11KW | 22KW | 33KW | ||
Input voltage rang (DC) | 0-800V | 0-800V | 0-800V | ||
MPPT Voltage range (DC)(DC) | 150V-700V | 150V-700V | 150V-700V | ||
Max. Input current (DC) | 22.4A | 44.9A | 67.3A | ||
Rated current | 20.4A | 40.8A | 61.2A | ||
THD Current harmonic | <3%(at rated power) | ||||
Power factor | >0.99 | ||||
Max. efficiency | 98% | ||||
Allowable grid voltage range (AC) | 220V/380V/440V/480V (Three-phase)±20% | ||||
Allowable grid frequency range | 50Hz/60Hz±10% | ||||
Automatic operation conditions | DC input and power grid meet the requirements, and the inverter operates automatically | ||||
Restart time after power failure | 5min (adjustable) | ||||
General parameters | |||||
Function | Rectification, DC output, output voltage control, output current control, Dump load control, control parameter setting, wind turbine curve setting | ||||
Automatic protection | Control part: Over voltage protection, over current protection, reverse connection protection, lightning arrester Inverter part: Polarity reverse connection protection, short circuit protection, island effect protection, LVRT, overheat protection, overload protection, ground fault protection, etc |
||||
Display | Touch screen, LCD | ||||
Monitoring content | Fan voltage, current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speed | ||||
Protection level | IP20(Indoor)IP65 (Outdoors) | ||||
Telematics | RS485/USB/GPRS/WIFI/Ethernet (optional) | ||||
Environment | Operating amb. Temp. & Hum -30-60°C,<90% no condensation | ||||
Noise (1m) | <40dB | ||||
Refrigeration mode | Forced air cooling | ||||
Size / weight | |||||
Controller size / weight | 400*230*550mm 23kg | 500*230*620mm 35kg | 500*230*620mm 38kg | ||
Dump load size / weight | 690*450*530mm 36kg | 980*880*540mm 70kg | 980*880*540mm 70kg | ||
Inverter size / weight | 690*275*770mm 42kg | 690*275*770mm 58kg | 690*275*770mm 65kg |
On grid wind turbine controller | WGMC3K380 | WGMC5K380 | ||
Wind turbine input | ||||
Power | 3KW | 5KW | ||
Max. Control power | 6KW | 10KW | ||
Rated voltage of wind turbine (AC) | 380V | 380V | ||
Input voltage range | AC 0-600V | AC 0-600V | ||
DC 0-900V | DC 0-900V | |||
Braking voltage (DC) | 550V±1% | 550V±1% | ||
Braking time min | 10-20 min | |||
Manual control | Manual brake | |||
Automatic control function | Dump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake, * electromagnetic brake | |||
* PV. Input | ||||
Rated power (increased) | 3KWp | 5KWp | ||
Working voltage (DC) | 550V / 660V | 550V / 660V | ||
DC output parameters | ||||
Output voltage range (DC) | 0-550V | 0-550V | ||
Constant voltage (DC) | 520V±1% | 520V±1% | ||
On grid wind turbine inverter | DMWG3KTL | DMWG5KTL | ||
Rated output power (AC) | 3KW | 5KW | ||
Max. Output power (AC) | 3.3KW | 5.5KW | ||
Input voltage rang (DC) | 0-800V | 0-800V | ||
MPPT Voltage range (DC) | 150V-700V | 150V-700V | ||
Max. Input current (DC) | 6.8A | 11.2A | ||
Rated current | 6.2A | 10.2A | ||
THD Current harmonic | <3%(at rated power) | |||
Power factor | >0.99 | |||
Max. efficiency | 98% | |||
Allowable grid voltage range (AC) | 220V/380V/440V/480V (Three-phase)±20% | |||
Allowable grid frequency range | 50Hz/60Hz±10% | |||
Automatic operation conditions | DC input and power grid meet the requirements, and the inverter operates automatically | |||
Restart time after power failure | 5min( adjustable) | |||
General parameters | ||||
Function | Rectification, DC output, output voltage control, output current control, Dump load control, control parameter setting, wind turbine curve setting | |||
Automatic protection | Control part: Over voltage protection, over current protection, reverse connection protection, lightning arrester Inverter part: Polarity reverse connection protection, short circuit protection, island effect protection, LVRT, overheat protection, overload protection, ground fault protection, etc |
|||
Display | Touch screen, LCD | |||
Monitoring content | Fan voltage, current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speed | |||
Protection level | IP20(Indoor)IP65 (Outdoors) | |||
Telematics | RS485/USB/GPRS/WIFI/Ethernet (optional) | |||
Environment | Operating amb. Temp. & Hum -30-60°C,<90% no condensation | |||
Noise (1m) | <40dB | |||
Refrigeration mode | Forced air cooling | |||
Size / weight | ||||
Controller size / weight | 360*230*480mm 17kg | 360*230*480mm 18kg | ||
Dump load size / weight | 400*400*250mm 12kg | 600*450*380mm 28kg | ||
Inverter size / weight | 550*225*770mm 49kg | 550*225*770mm 59kg |