Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Nature of Source Flow: | Passive inverter |
| Certification: | ISO9001, RoHS, CE |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Power Frequency Pure Sine Wave Inverter Features:
1.Complete isolation-type inverter technology, noiseless output.




50KVA off grid single phase inverter technical parameters
| Model | NB220-50KDZ | NB380-50KDZ | |
| DC input |
Input rated voltage | 220 VDC | 380 VDC |
| Input rated current | 252.5 A | 146 A | |
| Input DC voltage allowing range | 180-280 VDC | 350-500VDC | |
| AC input (AC bypass) |
Allow input voltage range | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% | |
| Input rated current | 455A / 417A / 227A /208A | ||
| Bypass transfer time | ≤100 ms (4ms optional) | ||
| AC output | Rated capacity | 50KVA | |
| Output rated voltage and frequency | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | ||
| Output rated current | 455A / 417A / 227A / 208A | ||
| Output voltage accuracy | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 2% | ||
| Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||
| Wave | Pure sine wave (Isolation transformer) | ||
| THD. | ≤3%(Linear load) | ||
| Overload capacity | 120%,10 minutes | ||
| Overcurrent capacity | 200%,10 seconds | ||
| Overload capacity | 120%,3 minutes,150%,10 second | ||
| Crest factor (CF) | 3:1 | ||
| Inverter efficiency | >92% | ||
| Working Environment | Dielectric strength | 1500VAC,1minute | |
| Noise (1m) | ≤50dB | ||
| Ambient temperature | -10ºC~+50ºC | ||
| Humidity | 0~90%, No condensation | ||
| Altitude | <2000m Higher than 2000m rated power should be reduced |
||
| Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
| Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | ||
| Equipped With Copper Transformer | Yes | ||
| Solar Charger | Optional | ||
| AC Charger | Optional | ||
| Generator Port | Optional | ||
| Size | 660*1300*1600 mm | ||
| Weight | 450 kg | ||
30KVA off grid single phase inverter technical parameters
| Model | NB110-30KDZ | NB220-30KDZ | NB380-30KDZ | |
| DC input |
Input rated voltage | 110 VDC | 220 VDC | 380 VDC |
| Input rated current | 303A | 151.5 A | 87.7A | |
| Input DC voltage allowing range | 90- 140VDC | 180-280 VDC | 320-500VDC | |
| AC input (AC bypass) |
Allow input voltage range | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% | ||
| Input rated current | 272A / 250A / 136 A /125A | |||
| Bypass transfer time | ≤40 ms (4ms optional) | |||
| AC output | Rated capacity | 30KVA | ||
| Output rated voltage and frequency | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | |||
| Output rated current | 272A / 250A / 136 A /125A | |||
| Output voltage accuracy | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 2% | |||
| Output frequency accuracy | 50Hz / 60Hz ± 0.05% | |||
| Wave | Pure sine wave (Isolation transformer) | |||
| THD. | ≤3%(Linear load) | |||
| Power factor (PF) | 0.8 | |||
| Overload capacity | 120%,10 minutes | |||
| Overcurrent capacity | 200%,10 seconds | |||
| Crest factor (CF) | 3:1 | |||
| Inverter efficiency | >92% | |||
| Working Environment | Dielectric strength | 1500VAC,1minute | ||
| Noise (1m) | ≤50dB | |||
| Ambient temperature | -10ºC~+50ºC | |||
| Humidity | 0~90%, No condensation | |||
| Altitude | <2000m Higher than 2000m rated power should be reduced |
|||
| Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |||
| Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | |||
| Equipped With Copper Transformer | Yes | |||
| Solar Charger | Optional | |||
| AC Charger | Optional | |||
| Generator Port | Optional | |||
| Size | 630*1000*1430 mm | |||
| Weight | 295 Kg | |||
20KW off grid three phase inverter technical parameters
| Type | NB216-20KSZ | |
| DC input | Input rated voltage | 216VDC |
| Input rated current | 102.9A | |
| Input DC voltage allowing range | 180-280VDC | |
| AC bypass | Allow input voltage range | 380VAC± 15% VAC |
| Input rated current | 30.4A | |
| Bypass transfer time | ≤100ms(4ms optional) | |
| AC output | Rated capacity | 20KW |
| Output rated voltage and frequency | Three phase 380VAC,50Hz/60HZ | |
| Output rated current | 30.4A | |
| Output voltage accuracy | 380VAC ± 2% | |
| Output frequency accuracy | 50Hz ± 0.05% | |
| Wave | Pure sine wave (Isolation transformer) | |
| THD. | ≤3%(Linear load) | |
| Power factor (PF) | 1 | |
| Overload capacity | 120%,10 minutes | |
| Overcurrent capacity | 200%,10 seconds | |
| Crest factor (CF) | 3:1 | |
| Inverter efficiency | >92% | |
| Working Environment | Dielectric strength | 1500VAC,1minute |
| Noise (1m) | ≤50dB | |
| Ambient temperature | -10ºC~+50ºC | |
| Humidity | 0~90%, No condensation | |
| Altitude | <2000m Higher than 2000m rated power should be reduced |
|
| Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |
| Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | |
| Ac charger | (optional) | |
| Battery, City grid (generator) priority | (optional) | |
| Size | 550×1050×1340mm | |
| Weight | 220KG | |
50KW off grid three phase inverter technical parameters
| Type | NB384-50KSZ | |
| DC input | Input rated voltage | 384VDC |
| Input rated current | 144.7A | |
| Input DC voltage allowing range | 320-480VDC | |
| AC bypass | Allow input voltage range | 380VAC± 15% VAC |
| Input rated current | 76A | |
| Bypass transfer time | ≤100ms(4ms optional) | |
| AC output | Output rated power | 50KW |
| Output rated voltage and frequency | Three phase 380VAC,50HZ (Three phase four wire) |
|
| Output rated current | 76A | |
| Output voltage accuracy | 380VAC ± 2% | |
| Output frequency accuracy | 50Hz ± 0.05% | |
| Wave | Pure sine wave (Isolation transformer) | |
| THD. | ≤3%(Linear load) | |
| Power factor (PF) | 1 | |
| Overload capacity | 120%,10 minutes | |
| Overcurrent capacity | 200%,10 seconds | |
| Crest factor (CF) | 3:1 | |
| Inverter efficiency | >92% | |
| Working Environment | Dielectric strength | 1500VAC,1minute |
| Noise (1m) | ≤50dB | |
| Ambient temperature | -10ºC~+50ºC | |
| Humidity | 0~90%, No condensation | |
| Altitude | <2000m Higher than 2000m rated power should be reduced |
|
| Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |
| Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | |
| Ac charger | (optional) | |
| Battery, City grid (generator) priority | (optional) | |
| Size | 630*1310*1573mm | |
| Weight | 430KG | |