Type | NB480-500KSZ | |
DC input | Input rated voltage | 480 VDC |
Input rated current | 1157 A | |
Input DC voltage range | 400-620 VDC | |
AC input (AC Bypass) |
Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC |
Input rated current | 1280A / 760A / 725A | |
Bypass transfer time | ≤100ms(Can be customized ≤4ms version) | |
AC output | Output rated power | 500KW |
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC ,50Hz / 60Hz | |
Output rated current | 1280A / 760A / 725A | |
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | |
Output frequency accuracy | 50Hz / 60Hz ±0.05% | |
Waveform distortion (THD). | ≤3% (Linear load) | |
Dynamic response time (Load 0←→100%) |
2ms | |
Power factor (PF) | 1 | |
Overload capacity | 120%,5 minutes;200%,3 seconds | |
Crest factor (CF) | 3:1 | |
Inverter efficiency | 96% | |
Working Environment | Dielectric strength | 1500VAC,1minute |
Noise (1m) | ≤50dB | |
Ambient temperature | -20ºC~+60ºC | |
Humidity | 0~90%, No condensation | |
Altitude | <6000m Higher than 2000m rated power should be reduced | |
Equipped with copper transformer | Yes | |
Pure Sine Wave | Yes | |
Communication mode | RS485,Wifi,GPRS,Ethernet (Modbus RTU protocol) | |
AC Charger | Optional | |
Solar Charger | Optional | |
Generator port | Optional | |
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |
Product Size | 1910*1160*1880mm | |
Product Weight | 1500-1800kg |
Type | NB480-600KSZ | |
DC input | Input rated voltage | 480 VDC |
Input rated current | 1389 A | |
Input DC voltage range | 400-620 VDC | |
AC input (AC Bypass) |
Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC |
Input rated current | 1550A / 910A / 870A | |
Bypass transfer time | ≤100ms (Can be customized ≤4ms version) | |
AC output | Output rated power | 600KW |
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC ,50Hz / 60Hz | |
Output rated current | 1550A / 910A / 870A | |
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | |
Output frequency accuracy | 50Hz / 60Hz ±0.05% | |
Waveform distortion (THD). | ≤3% (Linear load) | |
Dynamic response time (Load 0←→100%) |
2ms | |
Power factor (PF) | 1 | |
Overload capacity | 120%,5 minutes;200%,3 seconds | |
Crest factor (CF) | 3:1 | |
Inverter efficiency | 96% | |
Working Environment | Dielectric strength | 1500VAC,1minute |
Noise (1m) | ≤50dB | |
Ambient temperature | -20ºC~+60ºC | |
Humidity | 0~90%, No condensation | |
Altitude | <6000mHigher than 2000m rated power should be reduced | |
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |
Equipped with copper transformer | Yes | |
Pure Sine Wave | Yes | |
Communication mode | RS485,Wifi,GPRS,Ethernet (Modbus RTU protocol) | |
AC Charger | Optional | |
Solar Charger | Optional | |
Generator port | Optional | |
Product Size | 1910*1160*1880mm | |
Product Weight | 1800kg |