Customization: | Available |
---|---|
Output Power: | 250kw |
Battery Bank Voltage: | 360V/480V |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
DC TO AC inverter
Introduction
Our pure sine wave inverter is a dedicated power supply of a new generation of electric power and communication systems, we design and manufacture the inverter power supply according to the characteristics and requirements of the electric system, suitable for power system of power supply equipment high quality, high reliability requirements, are widely used in power system communication, carrier, monitoring, relay protection and emergency lighting. The power supply uses advanced sinusoidal pulse width modulation (SPWM) technology, the main circuit of Germany's Siemens IGBT module drive protection for Japan's Mitsubishi thick film circuit, with the advantages of high reliability, protection and full-featured, small waveform distortion, larger power and so on.
production features
(1) The main circuit adopts the United States INTEL microprocessor, Germany Siemens IGBT module, drive protection adopts Japan Mitsubishi movement, output partial adopts isolation transformer, safe and reliable
(2) SPWM pulse width modulation technology, the output is inverter, pure sine wave of low distortion
(3) Full-bridge circuit structure, applicable to any load
(4) DC input uses state-of-the-art anti-filling noise suppression technology, the AC input of multiple filtering to eliminate the interference of the electricity grid, communication equipment and other common DC panel without disturbing each other
(5) With a full range of power protection solutions and perfect self-detection and protection. DC input voltage is too low alarm, overload alarm, overheating alarm and short-circuit, the power will turn off the inverter output, troubleshooting, manually reset the power to work properly; Input under-voltage protection fault is cleared after the output will automatically resume
(6) Compact circuit structure, high efficiency, strong function
(7) Group-screen installation, elegant appearance
Adapt to the environment
1. For desolate area like mountain, island, pasturing area, etc.
2. For transportation system like beacon light, traffic light, street light, etc.
3. For communication system: unattached operation microwave middle station, optical
cable maintenance station, etc.
4. For photovoltaic power station, wind-solar power station, park charging station, family
power house, factory power station, etc.
5. For solar building: has good business future.
6. For the new technology application project.
off grid solar wind hybrid system:
Type | NB380-200KSZ | NB480-200KSZ | |
DC input | Input rated voltage | 380 VDC | 480 VDC |
Input rated current | 585 A | 463 A | |
Input DC voltage range | 320-496 VDC | 400-620 VDC | |
AC input (AC Bypass) |
Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
Input rated current | 550A / 300A / 290A | ||
Bypass transfer time | ≤100 ms (Can be customized ≤ 4ms version) | ||
AC output | Rated capacity | 200KVA | |
Output rated power | 160KW | ||
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC ,50Hz / 60Hz | ||
Output rated current | 550A / 300A / 290A | ||
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | ||
Output frequency accuracy | 50Hz / 60Hz ±0.05% | ||
Waveform distortion (THD). (Linear load) |
≤3% | ||
Dynamic response time (Load 0←→100%) |
2ms | ||
Power factor (PF) | 0.8 | ||
Overload capacity | 110%,3 minutes,150%,5 seconds | ||
Crest factor (CF) | 3:1 | ||
Inverter efficiency | 90% | ||
Working Environment | Dielectric strength | 1500VAC,1minute | |
Noise (1m) | ≤50dB | ||
Ambient temperature | -10ºC~+50ºC | ||
Humidity | 0~90%,No condensation | ||
Altitude | <2000m(Higher than 2000m rated power should be reduced) | ||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
Pure Sine Wave | Yes | ||
Equipped with copper transformer | Yes | ||
AC Charger | Optional | ||
Solar Charger | Optional | ||
Generator port | Optional | ||
Size(mm) | 1600*1000*2000mm | ||
Weight(kg) | 1400kg |
Type | NB380-250KSZ | NB480-250KSZ | |
DC input | Input rated voltage | 380 VDC | 480 VDC |
Input rated current | 731 A | 579 A | |
Input DC voltage range | 320-496 VDC | 400-620 VDC | |
AC input (AC Bypass) |
Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
Input rated current | 688A / 375A / 363A | ||
Bypass transfer time | ≤100 ms (Can be customized ≤ 4ms version) | ||
AC output | Rated capacity | 250KVA | |
Output rated power | 200KW | ||
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC ,50Hz / 60Hz | ||
Output rated current | 688A / 375A / 363A | ||
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | ||
Output frequency accuracy | 50Hz / 60Hz ±0.05% | ||
Waveform distortion (THD). (Linear load) |
≤3% | ||
Dynamic response time (Load 0←→100%) |
2ms | ||
Power factor (PF) | 0.8 | ||
Overload capacity | 110%,3 minutes,150%,5 seconds | ||
Crest factor (CF) | 3:1 | ||
Inverter efficiency | ≥96% | ||
Working Environment | Dielectric strength | 1500VAC,1minute | |
Noise (1m) | ≤50dB | ||
Ambient temperature | -10ºC~+50ºC | ||
Humidity | 0~90%,No condensation | ||
Altitude | <2000m(Higher than 2000m rated power should be reduced) | ||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
Equipped with copper transformer | Yes, 3 pcs | ||
Pure Sine Wave | Yes | ||
Size(mm) | Product Size: 1460*860*182mm | Package Size: 1600*1000*2000mm | |
Weight(kg) | Product Weight: 1200kg | Package Weight: 1400kg |
Type | NB480-300KSZ | |
DC input | Input rated voltage | 480 VDC |
Input rated current | 694 A | |
Input DC voltage range | 400-620 VDC | |
AC input (AC Bypass) |
Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC |
Input rated current | 830A / 450A / 430A | |
Bypass transfer time | ≤100 ms (Can be customized ≤ 4ms version) | |
AC output | Rated capacity | 300KVA |
Output rated power | 240KW | |
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC ,50Hz / 60Hz | |
Output rated current | 830A / 450A / 430A | |
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | |
Output frequency accuracy | 50Hz / 60Hz ±0.05% | |
Waveform distortion (THD). (Linear load) |
≤3% | |
Dynamic response time (Load 0←→100%) |
2ms | |
Power factor (PF) | 0.8 | |
Overload capacity | 110%,3 minutes,150%,5 seconds | |
Crest factor (CF) | 3:1 | |
Inverter efficiency | 90% | |
Working Environment | Dielectric strength | 1500VAC,1minute |
Noise (1m) | ≤50dB | |
Ambient temperature | -10ºC~+50ºC | |
Humidity | 0~90%, No condensation | |
Altitude | <2000m(Higher than 2000m rated power should be reduced) | |
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |
Pure Sine Wave | Yes | |
Equipped with copper transformer | Yes | |
AC Charger | Optional | |
Solar Charger | Optional | |
Generator port | Optional | |
Product Size(mm) | 1910*1160*1880mm | |
Product Weight(kg) | 1500kg |
Type | NB480-400KSZ | |
DC input | Input rated voltage | 480 VDC |
Input rated current | 926 A | |
Input DC voltage range | 400-620 VDC | |
AC input (AC Bypass) |
Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC |
Input rated current | 1024A / 608A / 580A | |
Bypass transfer time | ≤100 ms (Can be customized ≤ 4ms version) | |
AC output | Rated capacity | 400KVA |
Output rated power | 320KW | |
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC ,50Hz / 60Hz | |
Output rated current | 1024A / 608A / 580A | |
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | |
Output frequency accuracy | 50Hz / 60Hz ±0.05% | |
Waveform distortion (THD). (Linear load) |
≤3% | |
Dynamic response time (Load 0←→100%) |
2ms | |
Power factor (PF) | 0.8 | |
Overload capacity | 110%,3 minutes,150%,5 seconds | |
Crest factor (CF) | 3:1 | |
Inverter efficiency | 90% | |
Working Environment | Dielectric strength | 1500VAC,1minute |
Noise (1m) | ≤50dB | |
Ambient temperature | -10ºC~+50ºC | |
Humidity | 0~90%,No condensation | |
Altitude | <2000m(Higher than 2000m rated power should be reduced) | |
Equipped with copper transformer | Yes, 3 pcs | |
Pure Sine Wave | Yes | |
AC Bypass | Yes, when there is no enough battery power, will switch to Grid | |
AC Charger | Available, which is customized according to battery info | |
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |
Product Size | 1910*1160*1880mm | |
Product Weight | 1500-1800kg |
Type | NB480-500KSZ | |
DC input | Input rated voltage | 480 VDC |
Input rated current | 1157 A | |
Input DC voltage range | 400-620 VDC | |
AC input (AC Bypass) |
Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC |
Input rated current | 1280A / 760A / 725A | |
Bypass transfer time | ≤100 ms (Can be customized ≤ 4ms version) | |
AC output | Rated capacity | 500KVA |
Output rated power | 400KW | |
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC ,50Hz / 60Hz | |
Output rated current | 1280A / 760A / 725A | |
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | |
Output frequency accuracy | 50Hz / 60Hz ±0.05% | |
Waveform distortion (THD). (Linear load) |
≤3% | |
Dynamic response time (Load 0←→100%) |
2ms | |
Power factor (PF) | 0.8 | |
Overload capacity | 110%,3 minutes,150%,5 seconds | |
Crest factor (CF) | 3:1 | |
Inverter efficiency | 90% | |
Working Environment | Dielectric strength | 1500VAC,1minute |
Noise (1m) | ≤50dB | |
Ambient temperature | -10ºC~+50ºC | |
Humidity | 0~90%,No condensation | |
Altitude | <2000m(Higher than 2000m rated power should be reduced) | |
Equipped with copper transformer | Yes | |
Pure Sine Wave | Yes | |
AC Charger | Optional | |
Solar Charger | Optional | |
Generator port | Optional | |
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |
Product Size | 1910*1160*1880mm | |
Product Weight | 1500-1800kg |
Type | NB360-150KSZ | NB480-150KSZ | |
DC input | Input rated voltage | 360 VDC | 480 VDC |
Input rated current | 463A | 347 A | |
Input DC voltage range | 300-465 VDC | 400-620 VDC | |
AC input (AC Bypass) |
Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
Input rated current | 385A /227A / 217A | ||
Bypass transfer time | ≤100 ms (Can be customized ≤ 4ms version) | ||
AC output | Rated capacity | 150KVA | |
Output rated power | 120KW | ||
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC ,50Hz / 60Hz | ||
Output rated current | 385A /227A / 217A | ||
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 1% | ||
Output frequency accuracy | 50Hz / 60Hz ±0.05% | ||
Waveform distortion (THD). (Linear load) |
≤3% | ||
Dynamic response time (Load 0←→100%) |
2ms | ||
Power factor (PF) | 0.8 | ||
Overload capacity | 110%,3 minutes,150%,5 seconds | ||
Crest factor (CF) | 3:1 | ||
Inverter efficiency | 90% | ||
Working Environment | Dielectric strength | 1500VAC,1minute | |
Noise (1m) | ≤50dB | ||
Ambient temperature | -10ºC~+50ºC | ||
Humidity | 0~90%,No condensation | ||
Altitude | <2000m(Higher than 2000m rated power should be reduced) | ||
Pure Sine Wave | Yes | ||
Equipped with copper transformer | Yes, 3 pieces, make the inverter stable and safe, durable | ||
Battery priority | Optional | ||
Grid Power priority | Optional | ||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
Size(mm) | 1600*1000*2000mm | ||
Weight(kg) | 1000kg |