Customization: | Available |
---|---|
Type: | Combiner Box |
Structure: | Protection |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | DM-CB4 |
Basic | |
Max.PV Array Voltage | 1000V |
Max. PV Array parallel Inputs | 4 |
Rated fuse current(replaceable) | 10A/15A |
Allowable input current | 10A |
Output Circuit Breaker | 60A |
Max. Output current | 40A |
Diameter of wire of input PV array | 2.5 mm² |
Diameter of wire of output PV array | 8 mm² |
Diameter of wire for ground | 10 mm² |
PV dedicated SPD | Yes |
Anti-reverse | Yes |
IP | IP65 |
Size(mm) | 370*500*175mm |
Weight | 16KG |
Environment | |
Normal working temperature/humidity | -25ºC-70ºC,humidity 95% No Condensation,No corrosive gas |
Altitude(m) | <2000m |
Alarm | DC Arc fault state, voltage alarm, current alarm, temperature alarm etc |
Optional | |
Communication Interface | RS485/Modbus-RTU Protocol |
Current monitor for each string | Yes |
Signal Arrester | Yes |
Model | DM-CB06 |
Basic | |
Max.PV Array Voltage | 1000V |
Max. PV Array parallel Inputs | 6 |
Rated fuse current(replaceable) | 15A |
Allowable input current | 10A |
Output Circuit Breaker | 80A |
Max. Output current | 60A |
Diameter of wire of input PV array | 2.5 mm² |
Diameter of wire of output PV array | 12 mm² |
Diameter of wire for ground | 10 mm² |
PV dedicated SPD | Yes |
Anti-reverse | Yes |
IP | IP65 |
Size(mm) | 560*500*195mm |
Weight | 16KG |
Environment | |
Normal working temperature/humidity | -40ºC-70ºC,humidity 95% No Condensation,No corrosive gas |
Altitude(m) | <2000m |
Alarm | DC Arc fault state, voltage alarm, current alarm, temperature alarm etc |
Optional | |
Communication Interface | RS485/Modbus-RTU Protocol |
Current monitor for each string | Yes |
Signal Arrester | Yes |
Model | DM-CB10 |
Basic | |
Max.PV Array Voltage | 1000V |
Max. PV Array parallel Inputs | 10 |
Rated fuse current(replaceable) | 10A/15A |
Allowable input current | 10A/15A |
Output Circuit Breaker | 120A |
Max. Output current | 100A |
Diameter of wire of input PV array | 2.5 mm² |
Diameter of wire of output PV array | 20 mm² |
Diameter of wire for ground | 10 mm² |
PV dedicated SPD | Yes |
Anti-reverse | Yes |
IP | IP65 |
Size(mm) | 670*620*240mm |
Weight | 18KG |
Environment | |
Normal working temperature/humidity | -40ºC-70ºC,humidity 95% No Condensation,No corrosive gas |
Altitude(m) | <2000m |
Alarm | DC Arc fault state, voltage alarm, current alarm, temperature alarm etc |
Optional | |
Communication Interface | RS485/Modbus-RTU Protocol |
Current monitor for each string | Yes |
Signal Arrester | Yes |
Model | DM-CB16 |
Basic | |
Max.PV Array Voltage | 1000V |
Max. PV Array parallel Inputs | 16 |
Rated fuse current(replaceable) | 15A |
Allowable input current | 10A |
Output Circuit Breaker | 200A |
Max. Output current | 160A |
Diameter of wire of input PV array | 2.5 mm² |
Diameter of wire of output PV array | 32 mm² |
Diameter of wire for ground | 10 mm² |
PV dedicated SPD | Yes |
Anti-reverse | Yes |
IP | IP65 |
Size(mm) | 710*700*230mm |
Weight | 31KG |
Environment | |
Normal working temperature/humidity | -40ºC-70ºC,humidity 95% No Condensation,No corrosive gas |
Altitude(m) | <2000m |
Alarm | DC Arc fault state, voltage alarm, current alarm, temperature alarm etc |
Optional | |
Communication Interface | RS485/Modbus-RTU Protocol |
Current monitor for each string | Yes |
Signal Arrester | Yes |