Customization: | Available |
---|---|
After-sales Service: | Provide |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 11600/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical Parameters of the On Grid Yaw Wind Turbine Controller 30KW
Type | FKJ-GT-Y 30KW |
Wind turbine rated power | 30KW |
Wind turbine Max. power | 60KW |
Wind turbine rated voltage | AC380V |
Function | Rectifier,control, DC output |
Automatic protection function | Over voltage protection, network electric cut off protection, regulated supply output, arrester |
Manual function | Manual brake, reset, emergency switch, Yaw control, change OARS |
Display mode | Touch Screen User Name/Passwords: JNDM |
Display content | Wind turbine voltage, current, power; DC output voltage, DC output current, DC output power, total power.Yaw data Settings |
PWM constant voltage1 | ≥550dc |
Wind turbine deflection 45°(adjustable) | ≥550dc |
wind turbine 3-phase dump load voltage1 | 580±5Vdc |
wind turbine 3-phase dump load voltage2 | 580±5Vdc |
Wind turbine deflection 90°(adjustable) | 580±5Vdc |
Time-lapse of the wind turbine 3-phase dump load2 | 12-20 min |
Connecting wire of the PWM dump load | >25mm² |
Connecting wire of the dump load | >25mm² |
PWM dump load fuse | 4P 100A |
Fuse of DC output | 4P 150A |
Wind speed(adjustable) | ≥2m/s |
Wind direction(adjustable) | 0-360° |
Work environment temperature | -30-60°C |
Relative humidity | <90% No condensation |
Noise (1m) | <40dB |
Degree of protection | IP20(Indoor) IP65 (Outdoors) |
Cooling method | Forced air cooling |
*Communication interface (optional) | RS485/USB/GPRS/WIFI/Ethernet |
Size of the controller (mm) | 600*550*1220mm |
Weight of the controller | 80KG |
Size of the dump load (mm) | 950*800*450mm |
Weight of the dump load | 90KG |
Technical Parameters of the On Grid Wind Turbine Controller 15KW-30KW
Type | FKJ-GT15KW | FKJ-GT20KW | FKJ-GT30KW |
Wind turbine rated power | 15KW | 20KW | 30KW |
Wind turbine Max. power | 30KW | 40KW | 60KW |
Wind turbine rated voltage | AC380V-400V | AC380V-400V | AC380V-400V |
Function | Rectifier,control,DC output | ||
Automatic protection function | Over voltage protection, network electric cut off protection, regulated supply output, arrester | ||
Manual function | Manual brake, reset, emergency switch | ||
Display mode | LCD | ||
Display content | Wind turbine voltage, current, power; Solar voltage, current, power; DC output voltage, DC output current, DC output power, total power. | ||
PWM constant voltage | ≥520dc | ≥520dc | ≥520dc |
wind turbine 3-phase dump load voltage1 | 540±5Vdc | 540±5Vdc | 540±5Vdc |
wind turbine 3-phase dump load voltage2 | ------------ | 540±5Vdc | 550±5Vdc |
Time-lapse of the wind turbine 3-phase dump load2 | 12-20 min | 12-20 min | 12-20 min |
PWM dump load fuse | 50A | 63A | 80A |
Fuse of DC output | 63A | 80A | 100A |
Work environment temperature | -30-60°C | ||
Relative humidity | <90% No condensation | ||
Noise (1m) | <40dB | ||
Degree of protection | IP20(Indoor) IP65 (Outdoors) | ||
Cooling method | Forced air cooling | ||
Communication interface (optional) | RS485/USB/GPRS/WIFI/Ethernet | ||
Temperature compensation(optional) | -4mv/°C/2V,-35°C~+80°C,Accuracy:±1°C | ||
Size of the controller (mm) | 580*400*240 | 650*600*240 | 650*600*240 |
Weight of the controller | 25Kg | 36Kg | 38Kg |
Size of the dump load (mm) | 690*450*530 | 720*500*1300 | 720*500*1300 |
Weight of the dump load | 41Kg | 70Kg | 80Kg |
*Above parameter only for reference
1. Could be custom made to user specifications. 2, Could have solar power control subject to user demand.
Technical Parameters of the On Grid Wind Turbine (wind solar hybrid) Controller 5KW-10KW
Type | FKJ-GT5KW | FKJ-GT5KW | FKJ-GT20KW | |
Wind turbine rated power | 5KW | 5KW | 10KW | |
Wind turbine Max. power | 10KW | 10KW | 20KW | |
Wind turbine rated voltage | AC220V | AC380-400V | AC380-400V | |
Solar panels power(optional) | 1.5KW | 1.5KW | 10KW | |
Function | Rectifier,control,DC output | |||
Automatic protection function | Over voltage protection, network electric cut off protection, regulated supply output, arrester | |||
Manual function | Manual brake, reset, emergency switch | |||
Display mode | LCD | |||
Display content | Wind turbine voltage, current, power; Solar voltage, current, power; DC output voltage, DC output current, DC output power, total power. | |||
PWM constant voltage | ≥320dc | ≥520dc | ≥520dc | |
Wind turbine 3-phase dump load voltage | 350±5Vdc | 540±5Vdc | 540±5Vdc | |
Wind turbine 3-phase dump load time-lapse | 12-20 min | 12-20 min | 12-20 min | |
Solar panels fuse | 5A | 5A | 8A | |
PWM dump load fuse | 25A | 16A | 32A | |
Fuse of DC output | 32A | 20A | 40A | |
Work environment temperature | -30-60°C | |||
Relative humidity | <90% No condensation | |||
Noise (1m) | <40dB | |||
Degree of protection | IP20(Indoor) IP65 (Outdoors) | |||
Cooling method | Forced air cooling | |||
Communication interface (optional) | RS485/USB/GPRS/WIFI/Ethernet | |||
Temperature compensation(optional) | -4mv/°C/2V,-35°C~+80°C,Accuracy:±1°C | |||
Size of the controller (mm) | 510*360*240 | 510*360*240 | 580*400*240 | |
Weight of the controller | 18Kg | 18Kg | 23Kg | |
Size of the dump load (mm) | 600*450*380 | 600*450*380 | 690*450*530 | |
Weight of the dump load | 28Kg | 28Kg | 35Kg | |
*Above parameter only for reference
1. Could be custom made to user specifications. 2, Could have solar power control subject to user demand.
Technical Parameters of the On Grid Wind Turbine (wind solar hybrid) Controller 1.5KW-3KW
Type | FKJ-GT1.5KW | FKJ-GT2KW | FKJ-GT3KW |
Wind turbine rated power | 1.5KW | 2KW | 3KW |
Wind turbine Max. power | 3KW | 4KW | 6KW |
Wind turbine rated voltage | AC220V | AC220V | AC220V |
Solar panels power (optional) | 300W | 600W | 900W |
Function | Rectifier,control,DC output | ||
Automatic protection function | Over voltage protection, network electric cut off protection, regulated supply output, arrester | ||
Manual function | Manual brake, reset, emergency switch | ||
Display mode | LCD | ||
Display content | Wind turbine voltage, current, power; Solar voltage, current, power; DC output voltage, DC output current, DC output power, total power. | ||
PWM constant voltage | ≥320dc | ≥320dc | ≥320dc |
Wind turbine 3-phase dump load voltage | 350±5Vdc | 350±5Vdc | 350±5Vdc |
Wind turbine 3-phase dump load time-lapse | 12-20 min | 12-20 min | 12-20 min |
Solar panels fuse | 2A | 3A | 4A |
PWM dump load fuse | 10A | 10A | 16A |
Fuse of DC output | 16A | 16A | 20A |
Work environment temperature | -30-60°C | ||
Relative humidity | <90% No condensation | ||
Noise (1m) | <40dB | ||
Degree of protection | IP20 (Indoor) IP65 (Outdoors) | ||
Cooling method | Forced air cooling | ||
Communication interface (optional) | RS485/USB/GPRS/WIFI/Ethernet | ||
Temperature compensation (optional) | -4mv/°C/2V,-35°C~+80°C,Accuracy:±1°C | ||
Size of the controller (mm) | 510*360*240 | 510*360*240 | 510*360*240 |
Weight of the controller | 15Kg | 17Kg | 17Kg |
Size of the dump load (mm) | 410*360*120 | 410*360*120 | 400*410*250 |
Weight of the dump load | 7Kg | 9Kg | 13Kg |
*Above parameter only for reference
1. Could be custom made to user specifications. 2, Could have solar power control subject to user demand.